NTP 297-3601-316
08.01
August 2006
For Generic 602.20
2-45 Switch settings for printed circuit packs
Figure 2-31:
NT3T71 Maintenance Interface pack - switch locations
Note:
An option plug is inserted in one of the plug positions (A, B, or C),
depending upon the type of device connected to the NT3T71 pack, as
follows: A - for a DCE device such as a modem; B - for a DTE device such
as a maintenance terminal; C - for a 20 mA current loop.
Table 2-AS:
NT3T71 Maintenance Interface pack switch settings
Baud Rate
Switches
1
2
3
4
110
0
1
1
1
150
0
0
1
1
300
0
1
0
1
600
0
0
0
1
1200
0
1
1
0
1
4
(C)
(B)
(A)