NTP 297-3601-316
08.01
August 2006
For Generic 602.20
3-12 Switch settings for balance networks
Note:
Settings: 1 = ON, 0 = OFF
4.6-4.8
1402-1463
50.625
1
0
1
1
0
1
60
1
1
1
0
0
1
1
1
4.8-5.0
1463-1524
55.125
1
0
0
0
1
1
60
1
1
1
0
0
1
1
1
5.0-5.2
1524-1585
57.375
1
1
0
0
1
1
80
1
1
1
1
1
0
1
1
5.2-5.4
1585-1646
60.750
0
1
1
0
1
1
80
1
1
1
1
1
0
1
1
5.4-5.6
1646-1707
63.000
0
0
0
1
1
1
80
1
1
1
1
1
0
1
1
5.6-5.8
1707-1768
66.375
1
1
0
1
1
1
80
1
1
1
1
1
0
1
1
5.8-6.0
1768-1829
69.750
0
1
1
1
1
1
80
1
1
1
1
1
0
1
1
Table 3-J:
QNB65A Balance Network - switch settings for 22-gauge end-section H88 loaded cable
Length
Capacitance(
µ
F)
SP Switches
1
2
3
4
5
6
Resistance(
Ω
)
SQ Switches
1
2
3
4
5
6
7
8
Ft X
1000
Meters
1.2-1.3
366-396
0.0
0
0
0
0
0
0
40
1
1
1
1
0
1
1
1
1.3-1.5
396-457
2.250
0
1
0
0
0
0
40
1
1
1
1
0
1
1
1
1.5-1.7
457-518
4.500
0
0
1
0
0
0
40
1
1
1
1
0
1
1
1
1.7-1.9
518-579
7.875
1
1
1
0
0
0
60
1
1
1
1
0
1
1
1
1.9-2.0
579-610
10.125
1
0
0
1
0
0
60
1
1
1
1
0
1
1
1
2.0-2.1
610-640
11.250
0
1
0
1
0
0
60
1
1
1
1
0
1
1
1
Table 3-I:
(Continued)
QNB65A Balance Network - switch settings for 19-gauge end-section H88 loaded cable
Length
Capacitance
(
µ
F)
SP Switches
1
2
3
4
5
6
Resistance
(
Ω
)
SQ Switches
1
2
3
4
5
6
7
8
Ft X
1000
Meters
Содержание BayStack 600 Series
Страница 2: ......
Страница 6: ...NTP 297 3601 316 08 01 August 2006 For Generic 602 20 iv...
Страница 172: ...NTP 297 3601 316 08 01 August 2006 For Generic 602 20 3 36 Switch settings for balance networks...
Страница 176: ...4 4 Index NTP 297 3601 31608 01 August 2006 For Generic 602 20 printed circuit packs 2 2...
Страница 177: ......