Switch settings for balance networks 3-21
August 2006
08.01
NTP 297-3601-316
For Generic 602.20
Note 1: Settings: 1 = ON, 0 = OFF
Note 2: See Figure 3-4 for information about how to set the R1 and R2
potentiometers.
Note 1: Settings: 1 = ON, 0 = OFF
19-21
5791-6401
1.5
4..5
0.25
0
1
0
1
0
21-23
6401-7010
1.5
4.5
0.27
0
0
1
1
0
23-25
7010-7620
1.5
5
0.29
0
1
1
1
0
25-27
7620-8230
1.5
3
0.31
0
0
0
0
1
27-29
8230-8839
1.5
4
0.33
0
1
0
0
1
29-31
8839-9449
1.5
4
0.35
0
1
0
0
1
31-33
9449-10005
1.5
6
0.37
0
0
1
0
1
33-35
10005-10068
1.3
6
0.37
0
1
1
0
1
35-36
10068-10973
2
6
0.37
0
1
1
0
1
Table 3-N:
QNB65B Balance Network - switch settings for 22-gauge end-section non-loaded cable without
impedance compensator at far end of cable
Length
Resistance
Capacitance
Ft X 1000
Meters
R1
R2
Capacitance
Value (
µ
F)
SR Switches
1
2
3
4
5
6-7
1829-2134
5
0
0.17
0
1
0
0
0
7-9
2134-2743
4.5
0
0.19
0
0
1
0
0
9-11
2743-3353
4
1.5
0.19
0
0
1
0
0
11-13
3353-3962
3.5
4
0.19
0
0
1
0
0
13-15
3962-4572
3.5
3
0.19
0
0
1
0
0
15-17
4572-5182
2.5
2
0.19
0
0
1
0
0
17-19
5182-5791
2.5
2
0.19
0
0
1
0
0
19-21
5791-6401
2.5
3
0.23
0
0
0
1
0
21-23
6401-7010
2.5
3
0.23
0
0
0
1
0
23-25
7010-7620
3
4
0.25
0
1
0
1
0
25-27
7620-8230
3
4
0.25
0
1
0
1
0
27-29
8230-8839
3
4
0.27
0
0
1
1
0
29-31
8839-9949
3
4
0.27
0
0
1
1
0
31-32
9949-9754
3
5
0.29
0
1
1
1
0
Table 3-M:
(Continued)
QNB65B Balance Network - switch settings for 19-gauge end-section non-loaded cable without
impedance compensator at far end of cable
Length
Resistance
Capacitance
Ft X 1000
Meters
R1
R2
Capacitance
Value (
µ
F)
SR Switches
1
2
3
4
5
Содержание BayStack 600 Series
Страница 2: ......
Страница 6: ...NTP 297 3601 316 08 01 August 2006 For Generic 602 20 iv...
Страница 172: ...NTP 297 3601 316 08 01 August 2006 For Generic 602 20 3 36 Switch settings for balance networks...
Страница 176: ...4 4 Index NTP 297 3601 31608 01 August 2006 For Generic 602 20 printed circuit packs 2 2...
Страница 177: ......