Switch settings for balance networks 3-9
August 2006
08.01
NTP 297-3601-316
For Generic 602.20
Note 1: Settings: 1 = ON, 0 = OFF
Note 2: Top setting (1 through 8) for configurations A, B, and D. Bottom setting
(8 through 1) for configuration C.
2375
723.9
0
0
1
1
0
0
1
1
1
0
0
0
1
0
2625
800.1
0
0
1
0
0
0
1
1
1
1
0
0
1
0
2875
876.3
0
0
1
1
1
1
0
1
0
1
1
0
1
0
3125
952.5
0
0
1
0
1
1
0
1
1
0
0
1
1
0
3375
1028.7
0
0
1
1
0
1
0
1
1
1
0
1
1
0
3625
1104.9
0
0
1
0
0
1
0
1
0
1
1
1
1
0
3875
1181.1
0
0
1
1
1
0
0
1
1
0
0
0
0
1
4125
1257.4
0
0
1
0
1
0
0
1
1
1
0
0
0
1
4375
1333.5
0
0
1
0
1
0
0
1
1
0
1
0
0
1
4625
1409.7
0
0
1
1
0
0
0
1
0
0
0
1
0
1
4875
1485.9
0
0
1
0
0
0
0
1
0
1
0
1
0
1
5125
1562.1
0
0
1
1
1
1
1
0
0
0
1
1
0
1
5375
1638.3
0
0
1
1
1
1
1
0
0
1
1
1
0
1
5625
1714.5
0
0
1
0
1
1
1
0
0
0
0
0
1
1
5875
1790.7
0
0
1
1
0
1
1
0
0
1
0
0
1
1
6000
1828.8
0
0
1
1
0
1
1
0
0
0
1
0
1
1
Table 3-H:
NT2X80AA Balance Network - switch settings for 26-gauge end-section H88 loaded cable
Length
S1 Switches
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
S2 Switches
1
2
3
4
5
6
6
5
4
3
2
1
Feet
Meters