Switch settings for printed circuit packs 2-128
August 2006
08.01
NTP 297-3601-316
For Generic 602.20
Note: Set switches toward option to be selected.
Note: Set switches toward option to be selected.
Note: Set switches toward option to be selected.
Note: Set switches toward option to be selected.
Note: Set switches toward option to be selected.
Table 2-DW:
QRY18 Office Repeater pack - switch settings for the line build-out option
Option
Switch 3 Position
Line build-out option OUT
N
Line build-out option IN
P
Table 2-DX:
QRY18 Office Repeater pack - switch settings for the fault/locate output option
Option
Switch 7 Position
Normal
W, Y
Side 1
Y, X
Side 2
W, Z
Table 2-DY:
QRY18 Office Repeater pack - switch settings for the signal loopback option
Option
Switch 6 Position
Loopback enabled
S, U
No loopback required
T, V
Table 2-DZ:
QRY18 Office Repeater pack - switch settings for the powering option
Option
Switch 10 Position
Two-cable system in all offices
E, K, G, M
One-cable system in powering office
J, F, L, H
One-cable system in looping office
J, F, L, H
One-cable system in “Through” office
J, F, G, M
Table 2-EA:
QRY18 Office Repeater pack - switch settings for the powering option (QRY18A through D,
Series A and B only)
Option
Switch 10 Position
Two-cable system in all offices
J, F, G, M
One-cable system in powering office
J, F, L, H
One-cable system in looping office
J, F, L, H
One-cable system in “Through” office
E, K, G, M