Switch settings for balance networks 3-23
August 2006
08.01
NTP 297-3601-316
For Generic 602.20
Note 1: Settings: 1 = ON, 0 = OFF
Note 2: See Figure 3-4 for information about how to set the R1 and R2
potentiometers.
Note 1: Settings: 1 = ON, 0 = OFF
Note 2: See Figure 3-4 for information about how to set the R1 and R2
potentiometers.
Note 1: Settings: 1 = ON, 0 = OFF
25-26
7620-7925
5
5
0.21
0
1
1
0
0
Table 3-Q:
QNB65B Balance Network - switch settings for 19-gauge end-section non-loaded cable with
impedance compensator at far end of cable
Length
Resistance
Capacitance
Ft X 1000
Meters
R1
R2
Capacitance
Value (
µ
F)
SR Switches
1
2
3
4
5
6-7
1829-2134
3.5
3
0.15
1
0
0
0
0
7-9
2134-2743
2.5
3.5
0.15
1
0
0
0
0
9-11
2743-3353
1.5
4
0.15
1
0
0
0
0
11-13
3353-3962
1
4
0.15
1
0
0
0
0
13-15
3962-4572
.5
3.5
0.15
1
0
0
0
0
15-17
4572-5182
1
3.5
0.23
1
0
1
0
0
17-18
5182-5486
1
4
0.39
1
1
1
0
0
Table 3-R:
QNB65B Balance Network - switch settings for 22-gauge end-section non-loaded cable with
impedance compensator at far end of cable
Length
Resistance
Capacitance
Ft X 1000
Meters
R1
R2
Capacitance
Value (
µ
F)
SR Switches
1
2
3
4
5
6-7
1820-2134
4
3
0.15
1
0
0
0
0
7-9
2134-2743
3
3.5
0.15
1
0
0
0
0
9-11
2743-3353
2.5
4
0.15
1
0
0
0
0
11-13
3353-3962
2.5
4
0.15
1
0
0
0
0
13-15
3962-4572
2
3.5
0.15
1
0
0
0
0
15-17
4572-5182
2
3.5
0.23
1
0
1
0
0
17-18
5182-5486
2
4
0.39
1
1
1
0
0
Table 3-P:
(Continued)
QNB65B Balance Network - switch settings for 26-gauge end-section non-loaded cable without
impedance compensator at far end of cable
Length
Resistance
Capacitance
Ft X 1000
Meters
R1
R2
Capacitance
Value (
µ
F)
SR Switches
1
2
3
4
5
Содержание BayStack 600 Series
Страница 2: ......
Страница 6: ...NTP 297 3601 316 08 01 August 2006 For Generic 602 20 iv...
Страница 172: ...NTP 297 3601 316 08 01 August 2006 For Generic 602 20 3 36 Switch settings for balance networks...
Страница 176: ...4 4 Index NTP 297 3601 31608 01 August 2006 For Generic 602 20 printed circuit packs 2 2...
Страница 177: ......