45
WLAN Cable Access Point 6220 NTPM99CA 01 Rel 1.0 Issue 3 Dec 2004
Drop Cable Connection
Step Action
1.
Prepare “F series Coaxial Cable”, connector and all required Tools for
Terminator, Coring, Jacket stripper and Compression
2.
Remove the outer jacket/armor to expose the inner cable. Fold exposed
braid back over jacket. Leave foil attached to dielectric.
Figure 3-17
Drop Cable
3.
Push connector onto the cable until the cable dielectric is flush with the
connector post face. Approximately 1/4 inch (6.4mm) of center
conductor will protrude beyond the end of the connector nut.
Figure 3-18
Drop Connector Design
4.
Slightly angle the connector/cable and insert
into the compression tool area between the
plunger tip and the cable gate allowing the
center conductor to enter the center
conductor guide. Push the cable into the
cable gate. Compress the connector by
squeezing the tool handles together until a
positive stop is reached.
5.
Remove the connector/cable from the tool by opening the cable gate to
release the assembly from the tool.
In order to prevent damage to the connector on APU enclosure, cut the
pin of N to F type adapter to the length of 0.59inch (15mm) with a
cutting tool
Содержание 6220
Страница 3: ...3 Publication history December 2005 Issue 1 Issued for WLAN Cable Access Point 6220 APU CSU ...
Страница 12: ......
Страница 18: ...18 WLAN Cable Access Point 6220 NTPM99CA 01 Rel 1 0 Issue 3 Dec 2004 Figure 1 6 Inner Panel APU ...
Страница 36: ...37 WLAN Cable Access Point 6220 NTPM99CA 01 Rel 1 0 Issue 3 Dec 2004 Figure 3 4 NTA 2412 Antenna Assembly ...
Страница 51: ...52 WLAN Cable Access Point 6220 NTPM99CA 01 Rel 1 0 Issue 3 Dec 2004 Figure 3 26 LED Visual Checking Procedure ...
Страница 119: ...120 WLAN Cable Access Point 6220 CSU NTPM99CA Rel 2 0 Issue 5 Dec 2005 802 11g 802 11b ...