WLAN Cable Access Point 6220 NTPM99CA 01 Rel 1.0 Issue 3 Dec 2004
Procedure 1-4
Constructing Coaxial Cable and Connecting to the APU
Common Procedure
1.
Prior to installation, choose a coaxial cable type:
- Trunk & Distribution Cable and Connectors : “.500 series”
- Drop Cable and Connector : “F-type RG-59/6”
Note:
The APU standard cable modem operates within the range of +15 dBmV to -15
dBmV. Trunk Cable connection (Hard-line) which may introduce RF power levels
higher than 15 dBmV must have external device to attenuate the power being inserted
into
APU.
A.
Perform installation of the coaxial cable as below.
Action
Trunk Cable Connection
Step Action
1.
Prepare “.500 series Coaxial Cable”, GRS Type connector and all
required Tools for Terminator, Coring, Jacket stripper and Compression.
Figure 3-9
Trunk and Distribution Cable
Figure 3-10
Trunk Cable Design
2.
Remove the outer jacket/armor to expose the inner jacket, noting that
the removal of the outer jacket must be completed without scoring the
inner jacket.
Содержание 6220
Страница 3: ...3 Publication history December 2005 Issue 1 Issued for WLAN Cable Access Point 6220 APU CSU ...
Страница 12: ......
Страница 18: ...18 WLAN Cable Access Point 6220 NTPM99CA 01 Rel 1 0 Issue 3 Dec 2004 Figure 1 6 Inner Panel APU ...
Страница 36: ...37 WLAN Cable Access Point 6220 NTPM99CA 01 Rel 1 0 Issue 3 Dec 2004 Figure 3 4 NTA 2412 Antenna Assembly ...
Страница 51: ...52 WLAN Cable Access Point 6220 NTPM99CA 01 Rel 1 0 Issue 3 Dec 2004 Figure 3 26 LED Visual Checking Procedure ...
Страница 119: ...120 WLAN Cable Access Point 6220 CSU NTPM99CA Rel 2 0 Issue 5 Dec 2005 802 11g 802 11b ...