11.4 Console Tab
The Console tab displays fi ll-in fi elds for setting information and options
for the specifi c PERS-4200 Console.
User Password
Enter a new 4-digit User password for the Console. This is the password
that the User can use to call the Console from a remote telephone and
access User features. The factory default is 1-2-3-4.
Provider Password
Enter a new 6-digit provider password for the Console. This is the
password that allows the PERS provider to locally or remotely connect to
a Console and access programming. The factory default is 9-8-7-6-5-4.
Mode After Disconnect
Select the mode the Console will assume after programming when the
Console disconnects:
•
Home
— The Console will assume Home Mode after disconnect (default).
•
Away
— The Console will assume Away Mode after disconnect.
Transmission Supervision Interval
Supervised transmitters can send recurring status signals to the Console.
This option sets the length of time required before the Console will
recognize that a sensor’s status reports have
not
been received.
✓
NOTE: This setting does not affect supervision timing for smoke and
carbon monoxide detectors. These types of sensors are always set by the
Console to require reception of a status signal at least once every 24 hours.
Select one of the six options for the supervision interval: 12 hours, 24 hours
(default), 3, 7, 14, or 30 days.
This setting effects all non-smoke and
CO supervised sensors programmed into the Console that have
status supervision enabled.
✓
NOTE: These settings are confi gurable only by the Dealer or Installer
based on expertise and experience, as agreed upon with the User prior
to installation.
✓
NOTE FOR UL APPLICATIONS: UL requires the Transmitter Supervision
Interval option to be set to 24 hours.
Emergency Siren
The Console contains an emergency siren that can sound for fi ve minutes
when an emergency alarm is triggered, or until the report to the Central
Station is complete. The default for the siren is enabled. Optionally the
siren can be disabled by un-checking this option box.
✓
NOTE: This setting does not affect emergency alarms from smoke and
carbon monoxide detectors. These types of sensors always trigger the
emergency siren regardless of this setting.
Voice Prompts
The Console contains a voice synthesizer that can announce system
alarms and status. The default for the voice prompts is enabled. Optionally,
the voice prompts can be disabled by un-checking this option box.
RA4200 Console Tab