19
Public Switched Telephone Network (PSTN) Reporting
Settings for dial-up reporting using the telephone network are set in this area.
Account Number
The account number can be up to 10 digits long.
The last four digits of
the account number will be used as the communicator’s account
number for 4x2 and CID format reports to the Central Station.
✲
IMPORTANT! THE ACCOUNT NUMBER FIELD IS REQUIRED.
• CID requires a 4-digit number.
• SIA requires a 6-digit number
• 4x2 requires a 4-digit number.
Enter the account number for the specifi c Console.
Reporting Format
Three Central Station PSTN reporting formats are available.
• CID (Contact ID)
• SIA (Security Industry Association)
• 4x2 (4 by 2)
Contact ID is the default format. Select one of the other formats as
required by the Central Station.
Dial Format
The default dialing format is DTMF tone dialing. If the telephone system
that the Console will be connected to does not support DTMF tone
dialing, select pulse dialing.
Dialing Tones Audible
By default dialing tones do not sound from the Console’s speaker. This
option is typically used for troubleshooting telephone issues.
Check this option box to have the Console speaker active during dialing.
Primary Telephone Number
The primary telephone number is the number that will be dialed fi rst
in the dialing sequence. The number can be up to 20 digits including
commas that each add a one second pause.
✲
IMPORTANT! THE PRIMARY TELEPHONE NUMBER FIELD IS REQUIRED.
Secondary Telephone Number
The secondary telephone number is the number that will be dialed
second in the dialing sequence if the primary number is unsuccessful.
The number can be up to 20 digits including commas that each add a
one second pause.
Split Reporting
The Console can report supervisory events to a supervisory telephone
number if split reporting is enabled. Split reporting is disabled by default.
When split reporting is enabled, reports for alarm events, reminder
message timeouts, activity window expirations, and Two-way audio calls
(if enabled) are made to the primary and secondary phone numbers.
Reports of home/away mode, Console trouble conditions, sensor trouble
conditions, and Automatic Status reports are made separately to the
supervisory phone number only.
Supervisory Telephone Number
The supervisory telephone number is the number that will be dialed to
report supervisory events if split reporting is enabled. The number can
be up to 20 digits including commas that each add a one second pause.
RA4200 Communicator Tab PSTN Reporting Fields