background image

12

10.3 The  Menu Bar

The menu bar provides access to each of the programs sub-menus. The 
icons below the menu bar are used to open, save, and print User Account 
Templates and perform various actions with the PERS-4200 Console.

Drop-down Menu Items and Icons

The sub-menus that can be accessed from the Menu Bar are:

File

NEW

Opens a blank Account Template. The common Console default values are 
already fi lled in.

OPEN

Loads a saved Account Template into the RA4200 workspace. Only one 
Account Template can be open at a time in the RA4200 workspace.

SAVE

Saves the open Account Template to the hard drive. A warning dialog will be 
displayed if the template will overwrite the existing fi le.

PRINT / PREVIEW

Opens the account information print preview window to allow printing of 
the active Account Template. Shows what will be printed on the screen with 
options to zoom in or print the document. Resulting printout is the entire 
content of the Account Template fi le and the Console’s event log in text 
format.

EXIT

Closes the RA4200 program. If the Account Template has changed, you will 
be asked if you want to save it.

Communication

CONNECT

Opens the Send/Receive window. Uses the telephone number and password 
from the open template. Sets up and starts a modem or COM port (local with 
USB) connection.

DISCONNECT

Terminates the connection between the RA4200 program and the 
PERS-4200 Console.

G

ET CONSOLE

Retrieves the Account Template from the PERS-4200 Console that is 
currently connected to the RA4200 program.

G

ET LO

G

Retrieves the Event Log from the PERS-4200 Console that is currently 
connected to the RA4200 program.

SET CONSOLE

Sends the Account Template from the RA4200 program to the PERS-4200 
Console that is currently connected.

CONSOLE TIME

Opens the Set Time window. This function can be used to set the date and 
time or get the date and time of the Console currently connected to the 
program. Daylight saving time can be enabled or disabled, and the start and 
end weeks of daylight saving time can be adjusted.

Tools

CLEAR EVENT LO

G

Deletes the logged events from the connected PERS-4200 Console. It is 
recommended that the Dealer retain data from the event log for a period of 
two years.

TEST IP REPORTIN

G

Sends a test IP message from the Console to the Central Station. Requires 
a modem or USB connection to the Console, and an Internet connection.

IMPORT OR EXPORT FILE VIEWER

For reading the content of an *.ra3 export fi le, or an *.ra5 / *.ra6 import fi le.

EXPORT FILE TO MANA

G

EMENT SERVER

Creates a confi guration export fi le to be sent to the Console using the 
Management Server. This feature requires an internet connection. This is an 
alternate way to change the Console confi guration. Think of the Management 
Server as being a mailbox (it does more). An export fi le has confi guration 
settings and is meant to be delivered to the PERS Console (as compared to 
an import fi le which has confi guration settings from the PERS and is meant 
to be delivered, the other way, to the RA4200 application). The Management 
Server serves as an in-between conduit.

 

NOTE: The export fi lename is the IP account number by default. 
This fi lename is used by the Management Server in sending a new 
confi guration to the PERS Console (with the matching IP account 
number). To change the IP account number in the Console via an export 
fi le, do the following:

1. 

Change the the IP Account number fi eld in the template (to the new 
number).

2. 

Use the “Export” function, and when presented with a choice to use 
the default IP account number as the fi lename (this would be the new 
number) or to use an alternate fi lename, select alternate. Enter the old IP 
account number in the corresponding fi eld and proceed with the export 
function.

The Management Server will then update the PERS Console (still with the 
old IP account number), and change its (IP account) number to the new one.

RETRIEVE IMPORT FILE FROM MANA

G

EMENT SERVER

Retrieve data that have been sent to the Management Server (from the 
Console). These will be *.ra5 / *.ra6 import fi les. This function will move these 
import fi les from the Management Server to the local PC.

MER

G

E IMPORT (*.RA5 / *.RA6) or EXPORT (*.RA3) FILE

Merges data from an import fi le into a matching account template. All export, 
import fi les in the specifi ed folder will be merged into their corresponding 
account template fi les (with the matching IP account number). Merging an 
export fi le is allowed as an option. Reopen the appropriate account template 
(*.ra1) in RA4200 to view the latest merged info.

Toolbox

PANEL FIRMWARE UPDATE (DfuSe)

Launch the Console fi rmware update tool. This feature requires a USB 
connection. The Console also needs to be put in fi rmware update mode.

SELECT PERS CONSOLE TYPE

Select the PERS Console family. This will enable/disable the appropriate 
data fi elds.

AUTOMATIC STATUS REPORT RANDOMIZATION

Enable this feature to randomize the time of reporting. There’s an option here 
to set the desired range of time.

CHAN

G

E PASSWORD

Select to change the password. The correct password is needed to enable 
saving the account template.

Help

CONTENTS

Opens the help Contents search window. Used for accessing the RA4200 
program’s built-in help fi le. Function key F1 also accesses the help fi le.

ABOUT RA4200

Displays the version number of the RA4200 software.

Содержание Linear PERS-4200

Страница 1: ...7016 C INK BLACK MATERIAL 20 LB MEAD BOND SIZE 8 500 X 11 000 TOLERANCE 125 SCALE 1 1 FOLDING ALBUM FOLD BINDING SADDLE STITCH BY BY USA Canada 800 421 1587 800 392 0123 760 438 7000 Toll Free FAX 800...

Страница 2: ...72 This electronic product and its backup battery are not to be thrown away with everyday waste It is your responsibility to dispose of electrical and electronics equipment by handing it over to a de...

Страница 3: ...14 Provider Password 14 Mode After Disconnect 14 Transmission Supervision Interval 14 Emergency Siren 14 Voice Prompts 14 Annunciate Trouble Indication 15 Annunciate Status with Home Button 15 Annunci...

Страница 4: ...ity timer reset devices to verify activity at the User s location 1 1 Console Features Voice Prompts A built in digital voice synthesizer can speak voice prompts in English or Spanish to guide the Use...

Страница 5: ...ctor triggers the CO alarm When a carbon monoxide alarm is activated the Console announces the gas alarm and a carbon monoxide report is sent to the Central Station Activity Switch or motion triggered...

Страница 6: ...where the activity timer will not be used a snap on button cover is supplied to hide the HOME button NOTE The HOME button cover cannot be easily removed once the cover is in place ANTENNA OPTION MODUL...

Страница 7: ...LEPHONE LINE WHILE THE CONSOLE IS REPORTING TO THE CENTRAL STATION ATTACH POWER SUPPLY CLAMP TO OUTLET WITH SCREW NOTE FOR DECORA STYLE OUTLETS FLIP CLAMP OVER SECURE POWER SUPPLY TO CLAMP WITH A ZIP...

Страница 8: ...file must be downloaded and installed in the Console s memory with the RA4200 upgrade utility Volume Controls Two volume controls are provided to customize the sound levels of the Console for the ins...

Страница 9: ...le the Dealer and Installer should review and understand these features thoroughly Activity Timer The activity timer is a feature that requires the User to press a button or activate a transmitter dur...

Страница 10: ...he Console is not operational and cannot receive or report alarms 5 4 Test Learn Mode Test Learn Mode is accessible using the TEST button on the Console This mode can be used to locally learn test or...

Страница 11: ...space for each account template file 6 3 RA4200 FAQ How does RA4200 connect to a Console RA4200 can connect to the Console two ways Remote connection over the telephone line using the computer s modem...

Страница 12: ...files 3 Browse to find the SETUP EXE file Double click on SETUP EXE and the installation program will start 4 Click the Next button to install the Remote Access software Follow the on screen instruct...

Страница 13: ...ireless sensor zones of the PERS 4200 Console Each sensor zone displays its sensor ID number sensor type supervision option two way audio option and the current sensor battery and supervision status C...

Страница 14: ...ort file to be sent to the Console using the Management Server This feature requires an internet connection This is an alternate way to change the Console configuration Think of the Management Server...

Страница 15: ...ake it easy to link each file with an installation Keep these files in a safe location If a file is lost or deleted it can be recreated by retrieving the programmed information from an already program...

Страница 16: ...xide detectors These types of sensors are always set by the Console to require reception of a status signal at least once every 24 hours Selectoneofthesixoptionsforthesupervisioninterval 12hours 24hou...

Страница 17: ...BLE HOME MODE ONLY to sound and report temperature alerts only while the Console is in Home Mode The default set point for the low temp alert is 40 F 4 4 C The default set point for the high temp aler...

Страница 18: ...from a wireless sensor two options are available to control when the Console reports a low sensor battery Option 1 When a low battery signal is received from a sensor the Console will immediately rep...

Страница 19: ...replacing transmitters in field units easier Select AUTO DETECT for a sensor zone to automatically detect if a wireless transmitter is sending status signals Once the Console detects status signals fr...

Страница 20: ...ck option is selected the Two way audio setting will automatically adjust for the reporting method chosen PSTN or IP reporting PSTN Dialing Sequence The Console will make multiple attempts to make a c...

Страница 21: ...peaker active during dialing PrimaryTelephone Number The primary telephone number is the number that will be dialed first in the dialing sequence The number can be up to 20 digits including commas tha...

Страница 22: ...rmed for cellular reporting Note that an appropriate mobile terminated voice service plan is needed to use this feature The Two Way Audio Mode must also be enabled for callback to work Event Account N...

Страница 23: ...or the device Dealers will also have to change the configuration of the Console to use the gprs02 motient net APN IP service field to support call back See the example of the typicalTelit m2mAIR Devic...

Страница 24: ...Mode and announce FW Version and HW Version Press the HELP button while in Test Mode Console checks the presence of hardware if a Cellular Module is installed the Console announces Cellular module det...

Страница 25: ...ce 0 Console power failure OR 0 Console power restored Report Fall Detection Fall detection is not supported by the PERS 4200 Console This feature only works with 2GIG fall detection sensors when used...

Страница 26: ...g delay is OFF Two way Audio Mode The Console supports Two way audio communications with the User through the Console s speaker and microphone The default sets all Console sensors to have Two way audi...

Страница 27: ...e intervals based on the first message annunciated Pressing the CANCEL button cancels all of the reminder messages within the same timeout interval Reminder Settings The reminder settings globally aff...

Страница 28: ...e for the ride or appointment to announce during the message 5 Check the SLOT ENABLE check box to enable the reminder message time slot The schedule displayed for the time slot will be grayed until it...

Страница 29: ...played in the RA4200 connection status area 5 The modem will place a call to the Console wait a few rings then hang up This readies the Console to answer a call The modem will call the Console again t...

Страница 30: ...time and date If daylight saving time is enabled verify the start and stop dates Press SET TIME to update the Console s date and time Press DONE 4 Press SET CONSOLE The template will be sent to the C...

Страница 31: ...nine to hang up 0 Press zero for main menu If selecting a new format the Console will announce over the telephone 0 Report format is reporting format press pound to accept or press star to change Pres...

Страница 32: ...ss and release the TEST button again The Console will announce 0 Ready to learn sensor Zone number 3 Activate the sensor to learn The Console will announce 0 Fire Activity Emergency or Carbon Monoxide...

Страница 33: ...unce 0 Fire Activity Emergency or Carbon Monoxide sensor zone number full or low signal If the sensor tested has a low battery the Console will announce 0 Sensor low battery zone number 3 When finishe...

Страница 34: ...hen enabled supervisory trouble and remote access events are logged Remote access RA4200 sessions Console supervisory events AC power low battery phone trouble Sensor supervisory events supervision lo...

Страница 35: ...he FILE menu select PRINT PREVIEW or on the toolbar click the PRINT icon 3 The Account Information print preview window will be displayed The preview shows the account template contents detailed on se...

Страница 36: ...he RA4200 will disconnect the Console and the Console will reset 12 Click QUIT to exit the DfuSe utility 13 Configure the Console with the RA4200 as required NOTE Should any problems happen during the...

Страница 37: ...35 DfuSe Utility Connected to Console Firmware File Selection Verify and Target ID Selection Upgrading in Process DfuSe Device Warning Upgrade Complete...

Страница 38: ...0 76 ZA LOW TEMP RESTORE 3159 00 77 ZR FIRE SMOKE ALARM 1111 XX 2 10 SENSOR FA FIRE SMOKE LOW BATTERY 1 1384 XX 2 40 SENSOR FT FIRE SMOKE SUPERVISORY 1200 XX 2 40 SENSOR FS FIRE SMOKE SUPERVISORY REST...

Страница 39: ...nd AC power status ANNUNCIATE PHONE LINE AC STATUS must be selected on the Console tab 10 The Console will only announce Home Mode when manually switched from Away Mode using the HOME button 11 To rep...

Страница 40: ...OLE CELL MODULE PRESENT Opening Port COM30 Initializing Com Port Sending password Login Success Get status data Console Type Standard Console Protocol Ver 5 Hardware Ver 0 Firmware Ver 2 4 0 Data Vers...

Страница 41: ...A CID18 Extended CID58 Extended REMOTE PROGRAMMING PASSWORD 6 Digits REMOTE COMMUNICATIONS PASSWORD 4 Digits ACCOUNT NUMBER LENGTH FIBRO IP SIA 10 digits PSTN SIA 6 digits PSTN CID and 4x2 4 digits PR...

Страница 42: ...applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit acc...

Страница 43: ...odem connection 27 Modem testing 10 Mode setting 24 Mode switch reporting 23 Mode table 37 Multi language support 6 N Night mode 7 15 Not connected indicator 27 28 Notes 13 Not ready mode 6 8 O Option...

Страница 44: ...Copyright 2016 Nortek Security Control LLC 237016 C USA Canada 800 421 1587 800 392 0123 760 438 7000 Toll Free FAX 800 468 1340 www nortekcontrol com...

Отзывы: