Form
I-A C (2-17),
Page
3
Massachusetts
Requirements
California Warning
Label
1.3 Warranty
1.4 Installation
Codes
1.2 General
Information
If this system is being installed in the Commonwealth of Massachusetts, it must be
installed by a licensed plumber or licensed gas fitter.
If this system is being installed in the state of California, the installer MUST attach the
California warning label on the outside of the heat section access panel.
The California Warning label, P/N 196977, is shipped in the “Literature Bag”.
Select a dry, clean location on the heat section access panel and adhere the label.
The units contained in this manual are design-certified to ANSI and CSA standards
by ETL. These models are approved for installation in the United States and in
Canada.
The units are approved for use with either natural gas or propane. The type of gas
for which the air curtain is equipped and the correct firing rate as shown on the rating
plate attached to the unit.
Electrical characteristics are shown on the unit rating plate.
These units must be installed in accordance with local building codes. In absence
of local codes in the United States, the unit must be installed in accordance with the
National Fuel Gas Code NAPA/ANSI Z223.1a (latest edition) or CAN/CSA-B149.1
and B149.2. (See Paragraph 1). These codes are available from CSA Information
Services 1-800-463-6727. Local authorities having jurisdiction should be consulted
before installation is made to verify local codes and procedure requirements.
This manual includes installation, operation and spare parts information. Before
beginning any procedure, carefully review the information, paying particular attention
to the warnings. If you do not have knowledge of local requirements, check with the
local agencies who might have requirements concerning the installation. Become
familiar with the requirements of your particular installation and make preparations for
necessary supplies, equipment and manpower.
These air curtains are
ONLY
for indoor applications designed to operate at an
ambient temperature range between 5°F (-15°C) to 86°F (30°C).
Never place or rest anything, especially ladders against the air curtain.
The installation instructions in this manual apply to Gas Fired Air Curtain Models
AB 175 and AB 225.
Refer to limited warranty information on the warranty form in the “Literature Bag”
shipped with this unit.
If an extended warranty form applies, keep the extended warranty information for
future reference and verification of warranty.
Warranty is void if:
a)
The wiring is not in accordance with the diagram furnished with this unit.
b)
The unit is installed without proper clearances to combustible materials
c)
Unauthorized replacement parts are used.
2.0 Receiving,
Uncrating and
Preparing for
Installation
This unit was inspected and test operated at the factory prior to crating and was in
operating condition. If the unit was damaged in shipment, document the damage
with the transporting agency and contact your distributor. If you are an authorized
distributor, follow the FOB freight policy procedures.
Check the rating plate for the correct gas specifications and the
electrical
characteristics of the unit to insure that both utilities are compatible to with the gas
and electric services specific to the installation site.
Read this manual and become familiar with the installation requirements of your
particular unit. If you do not have knowledge of local requirements, check with the
gas company or other local agencies that may have requirements concerning this
installation.