MM371W / MM372W Installation Instructions
9
PUSH-TO-OPEN OPERATOR MOUNTING
Level
horiz
onta
l cros
s me
mber
Level o
pener
Gate in Closed Position
Gate Bracket
Post Bracket Assembly
Step 3
Step 4
●
With the gate in the CLOSED
position, use clamps to secure
the operator to the gate post and
center cross member of the gate.
●
Ensure that the operator is level.
●
With the operator arm temporarily
secured to the gate, check to
ensure there is at least 2 inches
of clearance between the operator
arm and gate. (See illustration in
Step 4 below).
20” MAX
CLEARANCE DIAGRAM
●
Disconnect the operator arm from the
gate bracket.
●
While supporting the operator, swing
the gate and operator to the OPEN
position.
●
Check for recommended clearances
and binding as shown.
●
Ensure that the necessary arm stroke
does not exceed 17 inches.
●
Make adjustments to the
mounting brackets to achieve the
recommended clearances.
TIP:
Turning the pivot bracket over
gives more hole alignment options for
the gate post pivot bracket assembly.
Your Property