Z-Wave Information
•
This thermostat can be operated in any Z-Wave network with other Z-Wave certified devices
from other manufacturers. All non-battery operated devices within the network will act as
repeaters regardless of vendor to increase reliability of the network.
•
Z-Wave is an Inter-operable two-way RF mesh networking technology designed for use with a
Z-Wave gateway/controller and other Z-Wave enabled devices.
Advanced Z-Wave® Information
This section is for the advanced user who has knowledge of the Z-Wave™ Command Classes. Please
note that the thermostat operates in Frequently Listening Receiver Slave (FLiR) mode, when it is
battery-powered.
Support for Association Groups
This thermostat supports Group 1, which can hold up to 5 nodes.
Group 1 Association is the default status report channel in Z-Wave+ lifeline requirements. Group 1
Alerts notify an associated device of a thermostat generated change. Thermostat generated changes
are changes that originate at or by the thermostat.
The following information is included in the lifeline report:
Low Voltage Alarm
When battery power is down to 30% or lower, the thermostat will send a low voltage alarm to the
Z-Wave Controller and display the low battery icon on the LCD.
Z-Wave Indicator
The thermostat's Z-Wave indicator will display when it receives Indicator CC from ZWave controller/
gateway.
Basic CC and Thermostat Mode CC
Basic Set On/Off is mapped to Thermostat Mode CC. Z-Wave controller/gateway sends a Basic Set CC
with value 0 (Off) to set Off mode, and sends value 255 (On) to set Auto mode.
Energy Saving Mode
Energy Saving Mode
is only available for those with a compatible Z-Wave controller/gateway that
supports energy saving mode.
The thermostat can be put into energy saving mode through ZWave by setting Thermostat Mode to
Energy Save Heat (0x0B), Energy Save Cool (0x0C), Away Heat (0x0D) or Away Cool(0x0E), from the
controller/gateway app.
When in Energy Saving Mode, the thermostat will display "ES Mode", and manage the climate
according Energy Heat/Cool Setpoint.
Exit Energy Saving Mode by setting the Thermostat Mode to Off/Heat/Cool/Auto through Z-Wave.
Please note that
Restore Default
would set the Energy Heat Set Point to 72 °F (22 °C) and Energy Cool
Set Point to 80 °F (26.5 °C), thus exiting Energy Saving Mode.
Scheduling
Scheduling
is only available for those with a compatible Z-Wave controller/gateway that supports
scheduling function to program the climate control setting at different times of day.
The thermostat supports up to 8 schedules (one Z-Wave Schedule Block, 8 Schedule IDs). You can
program the Heat Set Point, Cool Set Point, Humidity Mode, Moise Set Point, Dry Set Point, Fan Mode
in each schedule.
Please note that excluding the thermostat from the network sets all schedules to
Disabled
.
Performing
Restore Default
(in
Advanced Settings Menu, page 17
) sets all schedules to
Not Active
.
Supported Command Classes and Security
All supported command classes are available in S0, S2 unauthenticated and S2 authenticated
security class.
Command Class
Version Required Security Class
Association (Lifeline Association)
v2
Highest granted
Association Group Information
v3
Highest granted
Basic
Basic CC is mapped to thermostat Mode CC
v2
Highest granted
Battery
v1
Highest granted
Clock
v1
Highest granted
Device Reset Locally
v1
Highest granted
Firmware Update MD
v5
Highest granted
Humidity Control Mode
v1
Highest granted
Humidity Control Setpoint
v1
Highest granted
Humidity Operation State
v1
Highest granted
Indicator
v3
Highest granted
Manufacturer Specific
v2
Highest granted
Multi Channel Association
v3
Highest granted
Multilevel Sensor
v6
Highest granted
Powerlevel
v1
Highest granted
Security
v1
None
Security 2
v1
None
Schedule
v3
Highest granted
Supervision
v1
None
Thermostat Fan Mode
v3
Highest granted
Thermostat Fan State
v1
Highest granted
Thermostat Mode
v3
Highest granted
Thermostat Operating State
v2
Highest granted
Thermostat Setpoint
v3
Highest granted
Transport Service
v2
None
Version
v3
Highest granted
Z-Wave Plus Info
v2
None
• THERMOSTAT MODE V3
• THERMOSTAT SETPOINT V3
•
SENSOR MULTILEVEL V6
• CLOCK
•
HUMIDITY CONTROL MODE
•
HUMIDITY CONTROL SETPOINT
• THERMOSTAT FAN STATE
• THERMOSTAT FAN MODE V3
•
HUMIDITY CONTROL OPERATING STATE
• THERMOSTAT OPERATING STATE V2
• BATTERY
• DEVICE RESET LOCALLY