Heat Pump HVAC System Connections 

Note: 

For typical connections to a Heat Pump HVAC system, refer to the diagram on 

page 3

.

The  lower  section  shows 

HEAT PUMP HVAC

  terminal  connections.  The  upper  section  shows  the 

STANDARD HVAC

 terminal connections.

Figure 9. 

Heat Pump HVAC System Terminal Block Labeling

Figure 10. 

Heat Pump HVAC System Thermostat Terminal Block Connections

Connect the wires from the HVAC system to the corresponding terminals on the thermostat back 

terminal block. Use the table below as a guideline for connecting the wires.

Wire

Terminal

Y1

Connect to the Y1 terminal

Y2

Connect if a 2 stage system

G

Connect to the G terminal

RC

Connect to either R terminal

C

Connect to the C terminal. The C wire (24VAC common) Heat Pump systems typically 

have the C wire connected to the thermostat. If there is no 

C

 wire, batteries MUST be 

installed.

W1

Connect to the W1 terminal

O/B

Connect to the O terminal. Heat Pump setup must set changeover valve to correct 

O

 or 

B

 setting (See 

page 13

).

Notes: 

Ensure that the appropriate wires are screwed into the terminal blocks firmly. 

 

Gently pull on the wires to confirm the connection.

 

Push

 

all excess wiring back into the wall opening.

Dual Transformer Systems

For HVAC systems that have separate heating and cooling systems with their own 24VAC transformers, 

there is an “R” wire from the heating system and an “R” wire from the cooling system. 
For dual transformer systems, connect the “C” wire from the 

cooling 

system to the thermostat’s “C” 

terminal. 

DO NOT CONNECT THE “C” WIRE FROM THE HEATING SYSTEM.

IMPORTANT:

 Remove the Jumper connecting RC and RH terminals (see illustration below).

Figure 7. 

Dual Transformer HVAC System Thermostat Terminal Connections

Connect the wires from the HVAC system to the corresponding terminals on the thermostat back 

terminal block. Use the table below as a guideline for connecting the wires.

Wire

Terminal

Y2

Connect to the Y2 terminal 

(2-stage systems only)

Y or Y1

Connect to the Y1 terminal

G

Connect to the G terminal

COOL RC

Connect to RC terminal

C

Connect to C terminal (Cooling System C Wire, 

NOT

 Heating System C Wire)

HEAT RH

Connect to RH terminal

W or W1

Connect to W1 terminal

W2

Connect to W2 terminal 

(2-stage system only)

Standard

Heat Pump

HEAT PUMP SYSTEM 
TERMINAL WIRING

Y2

Y1

G

RC

RH

C

W1

W2

W3 HUM- HUM+

C

RH

RC

G

Y1

Y2

HUM- HUM+

O

/B

AUX/E

HUM-

HUM+

W3

W2

W1

C

RH

RC

G

Y1

Y2

C

RH

RC

G

Y1

Y2

HUM-

HUM+

O

/B

AUX/E

C

G

Standard

Heat Pump

Reference
Heat Pump
Terminals

(Labeled Wires)

O

 or B  

CONNECT IF 2
STAGE SYSTEM

Y

W

R

HUM-

HUM+

W3

W2

W1

C

RH

RC

G

Y1

Y2

C

RH

RC

G

Y1

Y2

HUM-

HUM+

O

/B

AUX/E

C

G

Standard

Heat Pump

Reference
Standard
Terminals

(Labeled Wires)

(Remove RC - RH Jumper)

W  

HEATING
SYSTEM

R

 WIRE

Y2

W2


OR 
Y1

COOLING
SYSTEM

R

 WIRE

COOLING
SYSTEM

C

 WIRE

Rh

R

W1

Rc

R

Содержание 2GIG Z-Wave Plus

Страница 1: ...N 10028238 Rev C INK BLACK PANTONE 3005 C MATERIAL 60 LB MEAD BOND SIZE 8 500 X 5 500 TOL 0 125 SCALE 1 1 FOLDING ALBUM FOLD BINDING SADDLE STITCH 72 SET 70 Fan Auto Cool F 47 User Guide 2GIG Security Automation System 2GIG Z Wave Plus Battery Powered Thermostat ...

Страница 2: ...Thermostat Operation 19 Main Thermostat Screen 19 Backlight and Button Operation 19 Display 19 Staging Indicators 19 Setting the System Mode 20 System Modes 20 Special Heat Pump Mode Emergency Heat 20 Setting the Heating or Cooling Temperature Setpoint 21 Automatic Setpoint Push 21 Frost Protection 21 Setting the Fan Mode 22 Fan Modes 22 User Customization 23 User preference settings 23 Error Disp...

Страница 3: ...HEATING AND COOLING TRANSFORMERS PLEASE REMOVE THE JUMPER CONNECTING RC AND RH TERMINALS FIRST AND THEN CONNECT HEATING R TO RH AND COOLING R TO RC PLEASE SEE PAGE 8 W2 HEAT STAGE 2 Typical Wiring for Heat Pump HVAC System THERMOSTAT CONNECTION C 24VAC COMMON HUM HUM W3 RH RC 24VAC POWER W1 HEAT STAGE 1 G FAN Y1 COMPRESSOR STAGE 1 Y2 COMPRESSOR STAGE 2 TYPICAL THERMOSTAT WIRING COLORS CAUTION VERI...

Страница 4: ...labels not included according to the terminal markings Some installations may have additional wires not shown in the example illustration below Y1 Y2 W1 W2 O B Use the thermostat terminal names marking not the wiring color to mark the wires Remove the old thermostat base CAUTION When removing thermostat don t let the wires slip into the wall and don t let the wires touch each other If the old ther...

Страница 5: ...y have one or two transformers The R wire connects differently depending on the system Single Transformer System Most HVAC systems have a single 24VAC transformer For these systems there is only one R wire that can be connected to either the thermostat s RC or RH terminal because a pre installed jumper wire connects the two terminals If installing a Standard HVAC system connect the wires from the ...

Страница 6: ...e separate heating and cooling systems with their own 24VAC transformers there is an R wire from the heating system and an R wire from the cooling system For dual transformer systems connect the C wire from the cooling system to the thermostat s C terminal DO NOT CONNECT THE C WIRE FROM THE HEATING SYSTEM IMPORTANT Remove the Jumper connecting RC and RH terminals see illustration below Figure 7 Du...

Страница 7: ...ction desired If the backlight is already on button touches work with the first touch Wait Mode The thermostat has a Minimum Off Time MOT delay after any heating or cooling cycle ends This delay prevents rapid heating cooling cycles and also provides short cycle protection for the system compressor This delay may be noticeable when you change a setpoint and it does not respond immediately due to t...

Страница 8: ...ype for Standard HVAC systems only Gas or Electric Changeover Type available with Heat Pump setup The changeover or reversing valve is used to change from heating to cooling operation The HVAC system is either a Changeover with Cooling type O or Changeover with Heating type B Most are changeover with cooling which is the default setting For Changeover with Cooling systems select WITH COOL This is ...

Страница 9: ...HID Home ID and ZNID Node ID located in the thermostat INFO screen For other specific tasks such as adding the thermostat to Scenes or Groups or deleting the thermostat from an existing network refer to the Z Wave controller instructions Removing from a Z Wave Network To remove the thermostat from the network use the following steps 1 Set your primary controller to exclude or remove mode to remove...

Страница 10: ...buttons to scroll through the menu options to the desired setting Touch FAN Select to change a setting Once it begins to flash use the buttons to select the desired setting Touch FAN Select to accept the new setting flashing will stop Select MODE Done to exit the option and return to the SETUP screen Feature Description Range Test Mode Temporary shorten Minimum Run Time Minimum Off Time to 10 seco...

Страница 11: ...ing off This will be Aux Stage off Threshold if 2nd Stage Heat Enable Aux Heat Enable in Heat Pump System 32 48 F 0 9 C Cool Stage 1 on Threshold Delta from Set point that stage 1 cooling start 34 45 F 1 7 C Cool Stage 1 off Threshold Delta from Set point that stage 1 cooling off 32 45 F 0 7 C Cool Stage 2 on Threshold Delta from Set point that stage 2 cooling start 36 46 F 2 8 C Cool Stage 2 off ...

Страница 12: ...rent setpoint of the current heating or cooling mode Adjust the setpoint temperature up or down with the buttons Note When in the Setpoint Change screen pressing the MODE button will switch the setpoint being displayed between the Heating and Cooling setpoints Default Figure 21 Accessing Setpoints Figure 22 Setpoint Change Screen Automatic Setpoint Push The cooling setpoint cannot be set below the...

Страница 13: ...play mode BACKLIGHT TIMEOUT Sets the time from last button touch that the backlight will turn OFF Range 10 30 seconds Default is 20 seconds Note Long backlight timeouts will reduce battery life SENSOR CALIBRATION Change the temperature calibration by 7 degrees Default is 0 Touch the UP or DOWN arrow buttons to change to the desired display temperature STATUS LINE Sets Status Line to Setpoints or C...

Страница 14: ...the Main Screen once either battery have been removed See Battery Installation page 10 Figure 26 Error Screen Figure 27 Battery Error Display Specifications Type Programmable thermostat for 24VAC 3H 2C non heat pump or 24VAC 3H 2C heat pump systems with humidifier de humidifier support Room Temperature Measurement Temp Scale Fahrenheit Celsius user selectable Temp Range 32 122 F 0 50 C Operating T...

Страница 15: ...ing Energy Heat Cool Setpoint Exit Energy Saving Mode by setting the Thermostat Mode to Off Heat Cool Auto through Z Wave Please note that Restore Default would set the Energy Heat Set Point to 72 F 22 C and Energy Cool Set Point to 80 F 26 5 C thus exiting Energy Saving Mode Scheduling Scheduling is only available for those with a compatible Z Wave controller gateway that supports scheduling func...

Страница 16: ...A PARTICULAR PURPOSE SHALL NOT EXCEED THE WARRANTY PERIOD PROVIDED HEREIN Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you NSC SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE BREACH OF ANY WRITTEN OR IMPLIED WARRANTY Some states do not allow the exclusion or limitation of incidental or consequ...

Страница 17: ...Copyright 2020 Nortek Security Control 10028238 Rev C or dial ...

Отзывы: