Clock Menu

Use the clock menu to set thermostat’s internal clock.

Figure 17. 

Clock Setup

Setting the Clock

1.  Touch any button to take thermostat out of sleep mode.
2. 

Touch 

MODE

 button for 5 seconds until, 

SETUP

 appears in status display line.

3.  Use 

 

buttons to select 

CLOCK

 in status display line.

4. 

Touch 

FAN (Select).

 

DAY

 will be displayed

5. 

Touch the 

 

buttons. 

TIME

 will be displayed.

6.  Use the 



 buttons to select the current time.

7. 

Choose 

FAN (Select)

MODE (Done)

MODE (Done)

.

INFO Menu

The INFO menu displays information about the thermostat. Use the 



 buttons to scroll through 

the various items. 

•  MODEL 2GIG-STZ-1
• 

VERSION Thermostat firmware version.

• 

Z-WAVE Z-Wave firmware version.

• 

SYSTEM TYPE displays current System Type setting.

• 

If System Type = Standard, FAN TYPE displays current Fan Type setting.

• 

If System Type = Heat Pump, CHANGEOVER TYPE displays current Change Over setting.

• 

Battery xx% = Battery Level (If battery powered)

If the thermostat is included in a Z-Wave network, items below will be present.

•  Z-Wave Node ID Node ID of Z-Wave Network
•  Z-Wave Home ID Home ID of Z-Wave Network

Factory Reset

WARNING: Please use this procedure only when the Z-Wave Primary Controller is 

missing or otherwise inoperable .

To reset the 2GIG-STZ-1

's Z-Wave parameters to Factory Settings (both Z-Wave and HVAC settings):

8. 

Touch and hold 

MODE 

button to go to Setup menu. 

9. 

Touch and hold 

MODE

 and the down arrow key (

) to enter Advanced Menu. 

10. 

Navigate to 

Restore Defaults

 to perform a factory reset.

Advanced System Settings Menu

The Advanced System Settings Menu provides for addition system setup options. These settings can 

affect system operation and should only be changed by qualified HVAC installers.
To access the Advanced System Settings menu, first touch and hold the 

MODE

 button to get into the 

Setup menu. While in the Setup Menu, touch and hold both the 

MODE

 and 

 buttons for 5 seconds. 

• 

Use the 



 buttons to scroll through the menu options to the desired setting. 

•  Touch 

FAN (Select)

 to change a setting. Once it begins to flash, use the 



 buttons to select 

the desired setting. 

•  Touch 

FAN (Select)

 to accept the new setting (flashing will stop). Select 

MODE (Done)

 to exit 

the option and return to the SETUP screen.

Feature

Description

Range

Test Mode

Temporary shorten Minimum Run Time, 

Minimum Off Time to 10 seconds for fast testing.

Y or N

Frost Protection Enable

When enabled, frost protection activates at 41 °F 

(5 °C) and stops at 47 °F (8 °C) regardless of System 

Mode and Heat / Cool Set Point.

Y or N

Aux Heat Enable

(Heat Pump System Only)

Use Auxiliary Heater as 2nd / 3rd Stage Heater.

Y or N

2nd Stage Heat Enable

Enables the second stage heat operation

Y or N

3rd Stage Heat Enable

(Standard System Only)

Enables the third stage heat operation

Y or N

2nd Stage Cool Enable

Enables the second stage cool operation

Y or N

Compressor in Heat 

Stage 3

(Heat Pump System Only)

Set 

No

 to disable compressor in Heat Stage 3 for 

energy saving.

Y or N

Minimum Run Time

Minimum Run Time before a heating / cooling 

cycle can turn off.

1 – 9 minutes

Minimum Off Time 

Minimum Off Time before a heating / cooling 

cycle can begin. 

5 – 9 minute

Heat Set point Max

Maximum Set point value of Heat Mode

32 – 90 °F 

(0 – 32 °C)

Cool Set point Max

Maximum Set point value of Cool Mode

61 – 122 °F 

(16 – 50 °C)

Heat Blower Off Delay

System blower delay off time after a heat call 

ends 

0 – 90 seconds

Cool Blower Off Delay

System blower delay off time after a cool call 

ends

0 – 90 seconds

Heat-Cool Delta

Minimum separation between Heating and 

Cooling Set point

36-48°F (2 – 9 °C)

Heat Stage 1 on Threshold

Delta from Set point that stage 1 heating start

34 - 45°F (1 - 7°C)

Heat Stage 1 off Threshold Delta from Set point that stage 1 heating off

32 - 45°F (0 – 7 °C)

Heat Stage 2 on Threshold

Delta from Set point that stage 2 heating start

(This will be Aux Stage on Threshold, if Aux Heat 

Enable & 2nd Stage Heat not Enable in Heat 

Pump System)

36 - 46°F (2 – 8 °C)

TOUCH AND HOLD
FOR 5 SECONDS

TOUCH THE 

▲▼

BUTTONS TO CHANGE
TO THE DESIRED MENU
ITEM, THEN TOUCH 

FAN (Select)

MENU CHOICES ARE DISPLAYED IN THE
STATUS DISPLAY LINE

Select

Done

CLOCK

Содержание 2GIG Z-Wave Plus

Страница 1: ...N 10028238 Rev C INK BLACK PANTONE 3005 C MATERIAL 60 LB MEAD BOND SIZE 8 500 X 5 500 TOL 0 125 SCALE 1 1 FOLDING ALBUM FOLD BINDING SADDLE STITCH 72 SET 70 Fan Auto Cool F 47 User Guide 2GIG Security Automation System 2GIG Z Wave Plus Battery Powered Thermostat ...

Страница 2: ...Thermostat Operation 19 Main Thermostat Screen 19 Backlight and Button Operation 19 Display 19 Staging Indicators 19 Setting the System Mode 20 System Modes 20 Special Heat Pump Mode Emergency Heat 20 Setting the Heating or Cooling Temperature Setpoint 21 Automatic Setpoint Push 21 Frost Protection 21 Setting the Fan Mode 22 Fan Modes 22 User Customization 23 User preference settings 23 Error Disp...

Страница 3: ...HEATING AND COOLING TRANSFORMERS PLEASE REMOVE THE JUMPER CONNECTING RC AND RH TERMINALS FIRST AND THEN CONNECT HEATING R TO RH AND COOLING R TO RC PLEASE SEE PAGE 8 W2 HEAT STAGE 2 Typical Wiring for Heat Pump HVAC System THERMOSTAT CONNECTION C 24VAC COMMON HUM HUM W3 RH RC 24VAC POWER W1 HEAT STAGE 1 G FAN Y1 COMPRESSOR STAGE 1 Y2 COMPRESSOR STAGE 2 TYPICAL THERMOSTAT WIRING COLORS CAUTION VERI...

Страница 4: ...labels not included according to the terminal markings Some installations may have additional wires not shown in the example illustration below Y1 Y2 W1 W2 O B Use the thermostat terminal names marking not the wiring color to mark the wires Remove the old thermostat base CAUTION When removing thermostat don t let the wires slip into the wall and don t let the wires touch each other If the old ther...

Страница 5: ...y have one or two transformers The R wire connects differently depending on the system Single Transformer System Most HVAC systems have a single 24VAC transformer For these systems there is only one R wire that can be connected to either the thermostat s RC or RH terminal because a pre installed jumper wire connects the two terminals If installing a Standard HVAC system connect the wires from the ...

Страница 6: ...e separate heating and cooling systems with their own 24VAC transformers there is an R wire from the heating system and an R wire from the cooling system For dual transformer systems connect the C wire from the cooling system to the thermostat s C terminal DO NOT CONNECT THE C WIRE FROM THE HEATING SYSTEM IMPORTANT Remove the Jumper connecting RC and RH terminals see illustration below Figure 7 Du...

Страница 7: ...ction desired If the backlight is already on button touches work with the first touch Wait Mode The thermostat has a Minimum Off Time MOT delay after any heating or cooling cycle ends This delay prevents rapid heating cooling cycles and also provides short cycle protection for the system compressor This delay may be noticeable when you change a setpoint and it does not respond immediately due to t...

Страница 8: ...ype for Standard HVAC systems only Gas or Electric Changeover Type available with Heat Pump setup The changeover or reversing valve is used to change from heating to cooling operation The HVAC system is either a Changeover with Cooling type O or Changeover with Heating type B Most are changeover with cooling which is the default setting For Changeover with Cooling systems select WITH COOL This is ...

Страница 9: ...HID Home ID and ZNID Node ID located in the thermostat INFO screen For other specific tasks such as adding the thermostat to Scenes or Groups or deleting the thermostat from an existing network refer to the Z Wave controller instructions Removing from a Z Wave Network To remove the thermostat from the network use the following steps 1 Set your primary controller to exclude or remove mode to remove...

Страница 10: ...buttons to scroll through the menu options to the desired setting Touch FAN Select to change a setting Once it begins to flash use the buttons to select the desired setting Touch FAN Select to accept the new setting flashing will stop Select MODE Done to exit the option and return to the SETUP screen Feature Description Range Test Mode Temporary shorten Minimum Run Time Minimum Off Time to 10 seco...

Страница 11: ...ing off This will be Aux Stage off Threshold if 2nd Stage Heat Enable Aux Heat Enable in Heat Pump System 32 48 F 0 9 C Cool Stage 1 on Threshold Delta from Set point that stage 1 cooling start 34 45 F 1 7 C Cool Stage 1 off Threshold Delta from Set point that stage 1 cooling off 32 45 F 0 7 C Cool Stage 2 on Threshold Delta from Set point that stage 2 cooling start 36 46 F 2 8 C Cool Stage 2 off ...

Страница 12: ...rent setpoint of the current heating or cooling mode Adjust the setpoint temperature up or down with the buttons Note When in the Setpoint Change screen pressing the MODE button will switch the setpoint being displayed between the Heating and Cooling setpoints Default Figure 21 Accessing Setpoints Figure 22 Setpoint Change Screen Automatic Setpoint Push The cooling setpoint cannot be set below the...

Страница 13: ...play mode BACKLIGHT TIMEOUT Sets the time from last button touch that the backlight will turn OFF Range 10 30 seconds Default is 20 seconds Note Long backlight timeouts will reduce battery life SENSOR CALIBRATION Change the temperature calibration by 7 degrees Default is 0 Touch the UP or DOWN arrow buttons to change to the desired display temperature STATUS LINE Sets Status Line to Setpoints or C...

Страница 14: ...the Main Screen once either battery have been removed See Battery Installation page 10 Figure 26 Error Screen Figure 27 Battery Error Display Specifications Type Programmable thermostat for 24VAC 3H 2C non heat pump or 24VAC 3H 2C heat pump systems with humidifier de humidifier support Room Temperature Measurement Temp Scale Fahrenheit Celsius user selectable Temp Range 32 122 F 0 50 C Operating T...

Страница 15: ...ing Energy Heat Cool Setpoint Exit Energy Saving Mode by setting the Thermostat Mode to Off Heat Cool Auto through Z Wave Please note that Restore Default would set the Energy Heat Set Point to 72 F 22 C and Energy Cool Set Point to 80 F 26 5 C thus exiting Energy Saving Mode Scheduling Scheduling is only available for those with a compatible Z Wave controller gateway that supports scheduling func...

Страница 16: ...A PARTICULAR PURPOSE SHALL NOT EXCEED THE WARRANTY PERIOD PROVIDED HEREIN Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you NSC SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE BREACH OF ANY WRITTEN OR IMPLIED WARRANTY Some states do not allow the exclusion or limitation of incidental or consequ...

Страница 17: ...Copyright 2020 Nortek Security Control 10028238 Rev C or dial ...

Отзывы: