9 Tabular overview of the program procedures
Capacity test
78
©
Nortec Electronics 2018
9.4 Capacity test
The program "P3: Capacity Test" is a specific part of the maintenance (program "P4: Mainte-
nance") and is used for capacity testing of aviation batteries. It meets the requirements of the bat-
tery manufacturer.
Example for NiCd-batteries:
================================
COPYRIGHT
NORTEC
2014-15 UL60 V 1.0 16.06.15
SN: 160001
--------------------------------
DATE: 28.06.15
BATTERY NO:
USER NO:
NOM. VOLTAGE: 24.00 V
CAPACITY: 040.0 Ah
PROGRAM: 322
NiCd Battery SAFT
Capacity Test
--------------------------------
PROGRAM START 10:38:02
VOLTAGE = 25.41 V
--------------------------------
P322:S1: 11:29:53
DISCHARGE
VOLTAGE = 20.70 V
CURRENT = 40.01 A
CAPACITY = 34.02 Ah
= 085 %
TIME = 051 MIN
--------------------------------
CELL 01: 1.052 V
CELL 02: 1.073 V
CELL 20: 1.032 V
--------------------------------
P322:S1: 11:32:53
DISCHARGE
VOLTAGE = 20.00 V
CURRENT = 40.01 A
CAPACITY = 36.07 Ah
= 090 %
TIME = 054 MIN
--------------------------------
BATTERY DISCHARGED
--------------------------------
CAPACITY = 36.07 Ah
= 090 %
--------------------------------
PROGRAM AUTOMATICALLY FINISHED
================================
9.4.1
Program 312: Capacity Test Valve Regulated Lead Acid Aircraft Battery