8 Program selection
The display screen for program 420
©
Nortec Electronics 2018
47
8.5.3
Program 420 Step 3
NiCd battery (manufacturer independent)
Program:
Maintenance
P420:S3: TOPPING CHARGE 1
31.05V
00.40A
04.02Ah
003MIN
15.01.15 20:42:43
--.-°C
1
Program number
Kind of treatment
4 = Maintenance
Battery type
20 = NiCd battery (manufacturer independent)
2
Step number
= S3
3
Step type
= TOPPING CHARGE 1
4
20:42:38
= present time
5
31.05
V
= present battery voltage
there is no voltage limit to 31
V.
6
0.40
A
= present charging current
The topping charge with 10-hours current
4
Ah/10
h = 0.4
A takes 1.5 hours. The reason
for doing this is to equalize the voltages of the
cells.
7
4.02
Ah
The display of the capacity continues
which means the inloaded capacity during
I-CHARGE 1 plus capacity for TOPPING
CHARGE 1.
5
6
7
4
3
2
1