8 Program selection
Principles for program selection
38
©
Nortec Electronics 2018
Maintenance (= Treatment 4)
This program is used to analyse lead acid-, NiCd- and Lithium batteries. Relevant data for battery
analysis will be recorded and illustrated. The actual capacity will be determined.
After completion of the treatment maintenance, the battery is fully charged.
Selection of the battery type passes through several testcycles. From time to time maintenance
works at the batteries are necesssary. The maintenance manuals of the battery manufacturer al-
ways apply.
I-Charge (= Treatment 5)
Using the program I-charge allows a free selection of charging current and charging time span.
Deep Discharge (= Treatment 6)
This program is used to deep discharge the battery according to the manufactuerers instructions.
Reconditioning (= Treatment 7)
This program is used for the reconditioning of a NiCd-battery according to manufacturers
instructions.
Constant Voltage Supply (= Treatment 8)
Using this treatment, the UL60 serves as a constant voltage supply.
Other battery = (battery type 00)
The device works as a laboratory power suppy with a performance of 40
V/60
A. Voltage and
current can be chosen in steps from 0.01
V/0.01
A.
With battery = (battery type 10 – 24)
If a battery type >0 is chosen, the device automatically selects the float-voltage for the chosen
battery which allows an unlimited connection of the battery to the UL60 without damaging it.