16
3.0 Directions for use
Parameter setting for xbo HTP OFR (only for:
EX-100 D/1
with factory settings)
Lamp
P
max
(operating range: 1000 and 2000W): max: power of the lamp.
When entered, an automatic control will avoid exceeding this value. Factory setting: is on 1000W.
Lamp
l
max
(operating range: 55A - 85A): max. admitted current of the lamp.
When entered, an automatic control will avoid exceeding this value. Factory setting: 55A.
Lamp
l
max
(operating range: 40 - 50A):
min. admitted current of the lamp.
When entered, an automatic control will avoid exceeding this value. Factory setting: 40A.
Lamp
stand-by
(operating range l
max
- l
min
): lamp stand-by current when contacts 11 and 12 of
J/P2 have been closed. When the contacts are closed, an automatic control will be change the
current according to the admitted operating range. Factory setting: 40A.
Lamp
set-point
(operating range: l
max
- l
min
: value of the current delivered in output.
Factory setting: 40A.
Remarks:
1) When entering an l
max
value lower than l
min
, l
min
will be set to l
max
. Enter a new l
min
value.
2) When entering a l
max
exceeding l
max
value, l
min
will correspond to l
max
.
EX-100 D/1
Lamp
P
max
2000W
1000W
Lamp
I
max
85A
55A
Lamp
I
min
50A
40A
Lamp
stand-by
50A
40A
Lamp
set-point
70A
50A
Содержание 4036538577789
Страница 1: ...1 INSTALLATION USER MANUAL SEARCHLIGHTS XENON SL40 R5 ...
Страница 10: ...10 2 3 Cut out main slave panel Hole dimensions for installing main panel ...
Страница 17: ...17 3 1 Program menu Parameter setting Example for 3000W Xenon ...
Страница 18: ...18 3 2 Program menu Parameter setting ...
Страница 20: ...20 3 4 Program menu Parameter mode setting ...
Страница 25: ...25 4 4 Wiring Searchlight XS 2000 with Power supply N3 80E ...
Страница 26: ...26 4 5 Wiring R5 XS1000 with external PSU PX 50N ...
Страница 27: ...27 4 6 Wiring Main panel with focus ...
Страница 31: ...31 4 10 Power supply EX 100 D 1 for 2000 3000W ...