background image

14

For 1600-2000W

N3-80E

These high quality recti

fi

 er power supplies have been expressly designed to ensure the correct 

operation and long life of short arc Xenon lamps. 
These units, developed to meet the recommendations of Xenon lamp manufacturers, are 

fi

 tted 

with special IREM transformers with adjustable magnetic shunt for continuous output regulation 
over the entire operating range.
The new and peculiar design guarantees a low acoustical noise, i.e. less than 55dB(A).
The special design, including an auxiliary 

fi

 lter unit, ensures a low ripple with a negligible starting

energy. Weight 105kg.
Further instructions in Installation guide for Recti

fi

 er see page 30.

Adjust
current
by
turning 
hand wheel.
Current
applied
to the lamp
should be 
for.

A:320 mm
B:380 mm
H:770 mm

Electric installation

The main operation panel requires 24V DC connected in series with a 3A slow fuse 
to the positive (+) conductor.

 

•  The switch requires 24V DC in addition to grounding.
•  Depending on the searchlight model it requires 115V AC or 230V AC.
•  Power supplied to the power supply unit must be 3-phase and PE.
•  Current supplied to the lamp unit must be speci

fi

 c, (see Technical data for speci

fi

 c type Omron).

Lamp set-point see page 30.

*To be able to turn o

  the searchlight from the main panel, the switch on top of the power supply   

  N3-80 must be in position “0” (Zero).

Note:  Disconnect the power when working on the equipment!
 

Electrical equipment must be installed by authorized personnel!

 

Check the polarity when connecting 24V DC!

 

All searchlight system equipment MUST BE connected to ground/earth!

*

Содержание 4036538577789

Страница 1: ...1 INSTALLATION USER MANUAL SEARCHLIGHTS XENON SL40 R5 ...

Страница 2: ...Manual for Xenon Searchlight XS 1000 R5 XS 2000 R5 1 x 230 VAC 50 60 Hz 1 x 115 VAC 50 60 Hz This manual refers to product Serial no ____________________ Controlled by ____________________ Date ____________________ ...

Страница 3: ... Parameter mode setting 20 4 0 Electrical Installation 21 4 1 Layout XS1000 22 4 2 Layout XS2000 23 4 3 Wiring Searchlight XS1000 with integrated Power supply NP 0725 24 4 4 Wiring Searchlight XS2000 with external Power supply N3 80E 25 4 5 Wiring Searchlight XS1000 with external Powers supply PX 50N 26 4 6 Wiring Main panel XS and SH with focus 27 4 7 Power supply NP 0725 for 500 1000W 28 4 8 Pow...

Страница 4: ...n order to stay in front Norselight would very much appreciate all comments that you may have regarding our quality products or services Customer Service The Customer Service department of GLAMOX Production GmbH Co KG will be pleased to help you when ordering spare parts for maintenance and repair work as well as in case of problems and questions Manufacturer Customer Service contact GLAMOX Produc...

Страница 5: ...hardened frontglass noise filters and a focus motor for adjustment of the light beam The motor housing contains a complete gear with motors for horizontal and vertical movement a thermostat driven heating element and the electronic control system Control Panel Main Operation Panel it contains the following functions Lamp On Off Joystick for horizontal and vertical movement Speed regulator for horiz...

Страница 6: ...6 1 1 Options Other RAL colours Upside down mounting Pedestal standard and custom sizes on request Special cable glands on request ...

Страница 7: ...1000W CFP 1000 115 VAC 50 60Hz Technical spec for all XS models IP Classification 56 Maximum ambient temperature 50ºC Minimum ambient temperature 40ºC Horizontal movement 360º Vertical movement 27 5º Inclination speed V H 4 s Colour RAL 9016 Forks Stainless steel Technical spec main panel IP Classification 67 front Maximum ambient temperature 50ºC Minimum ambient temperature 20ºC Connection termin...

Страница 8: ... IP classification IP20 Temperature ambient 5 45 C Input Voltage 185 265VAC single phase or double phase Cable Input max Ø 8 20mm Cable output DC max Ø 2 x 20mm Cable remote signal max Ø 20mm Dimensions ABH 265 x 436 x 440mm Weight 19 5kg PX 50N 1000W Art No 1009155 115V 1009156 230V IP classification IP20 Temperature ambient 0 40 C Input Voltage 100 132VAC single phase Input Voltage 208 230VAC si...

Страница 9: ...tion 1 2 3 4 Cable gland M20 M20 M25 M32 Cable Ø min max 6 13mm 6 13mm 9 17mm 13 21mm Cable entry Options are available Remote signal to rectifier LAN 24V DC 115V AC 230V AC DC from Xenon rectifier Entry Description 1 2 3 4 Cable gland M20 M20 Blind plug Blind plug Cable Ø min max 6 13mm 6 13mm Cable entry 115 V AC 230 V AC LAN XS 1000 XS 2000 ...

Страница 10: ...10 2 3 Cut out main slave panel Hole dimensions for installing main panel ...

Страница 11: ...n when the remote ON OFF signal is used 1 Ta 50 C max running time until the searchlight will switch off is 2 hours 2 Ta 45 C max running time until the searchlight will switch off is 6 hours 3 Ta 35 C and less the searchlight is continuously running Note After an automatic safety shutdown of the power supply due to overheating the input power of the search light L N has to be interrupted and connec...

Страница 12: ...1000W It is characterized by galvanic insulation a soft inrush current alow residual ripple value and a sta ble output current Weight 8 4kg Further instructions in Installation guide for Rectifier see page 28 ouse Settings 30A 500W Settings 50A 1000W Note Current adjustments when the bulb is switched on The switch SW1 must remain in OFF position when the remote ON OFF signal is used Setting 1000W ...

Страница 13: ...operation and long life of the lamp The units are fitted with a transformer with taps for output lamp power regulation and a special circuit to avoid the lamp turn off during the tap switching The cabinet equipped with carrying handles permits an easy inspection of the inside components Weight 63kg Further instructions in Installation guide for Rectifier see page 29 A 245mm B 595mm H 238mm ...

Страница 14: ...y turning hand wheel Current applied to the lamp should be for A 320 mm B 380 mm H 770 mm Electric installation The main operation panel requires 24V DC connected in series with a 3A slow fuse to the positive conductor The switch requires 24V DC in addition to grounding Depending on the searchlight model it requires 115V AC or 230V AC Power supplied to the power supply unit must be 3 phase and PE ...

Страница 15: ... 3000W short arc Xenon lamps meeting all the requirements of lamp manufacturers to ensure correct operation long life to the lamp and high reliability Weight 19 5kg Further instructions in Installation guide for Rectifier see page 31 Control devices 1 Synoptic panel 2 Output terminal block 3 Input terminal block 4 RS232 connector 5 Auxiliary connector ...

Страница 16: ...ic control will avoid exceeding this value Factory setting 40A Lamp stand by operating range lmax lmin lamp stand by current when contacts 11 and 12 of J P2 have been closed When the contacts are closed an automatic control will be change the current according to the admitted operating range Factory setting 40A Lamp set point operating range lmax lmin value of the current delivered in output Facto...

Страница 17: ...17 3 1 Program menu Parameter setting Example for 3000W Xenon ...

Страница 18: ...18 3 2 Program menu Parameter setting ...

Страница 19: ...naged through the synoptic panel press left decreasing key and right increasing key Press and hold one of the two setting keys for at least 2 seconds then enter the password within 30 seconds The current setting is now enable a question mark is present on the right side of the current value The lamp current range has to be within 40A and 85A Press The ON OFF key to switch on off the lamp Note under...

Страница 20: ...20 3 4 Program menu Parameter mode setting ...

Страница 21: ...AC Power supplied to the power supply unit must be 2 or 3 phase Current supplied to the lamp unit must be specific see Technical data for specific type Current applied to the lamp unit see page 31 EX100 D 1 is pre programmed Note Disconnect the power when working on the equipment Electrical equipment must be installed by authorized personnel Check the polarity when connecting 24V DC All searchligh...

Страница 22: ...D PP 6FKXW YHUPHUN 1 62 7KH FRS LQJ GLVWULEXWLRQ DQG XWLOL DWLRQ RI WKLV GRFXPHQW DV ZHOO DV WKH FRPPXQLFDWLRQ RI LWV FRQWHQWV WR RWKHUV ZLWKRXW H SUHVVHG DXWKRUL DWLRQ LV SURKLELWHG 2IIHQGHUV ZLOO EH KHOG OLDEOH IRU WKH SD PHQW RI GDPDJHV OO ULJKWV UHVHUYHG LQ WKH HYHQW RI WKH JUDQW RI D SDWHQW XWLOLW PRGHO RU RUQDPHQWDO GHVLJQ UHJLVWUDWLRQ HLWHUJDEH VRZLH 9HUYLHOIlOWLJXQJ GLHVHV RNXPHQWV 9HUZHUW...

Страница 23: ...UXQJ 6XE IRU UV I U 6XE E UV GXUFK H U UDZLQJ 1R HLFKQJV 1U 6FDOH 6NDOD PP 6FKXW YHUPHUN 1 62 7KH FRS LQJ GLVWULEXWLRQ DQG XWLOL DWLRQ RI WKLV GRFXPHQW DV ZHOO DV WKH FRPPXQLFDWLRQ RI LWV FRQWHQWV WR RWKHUV ZLWKRXW H SUHVVHG DXWKRUL DWLRQ LV SURKLELWHG 2IIHQGHUV ZLOO EH KHOG OLDEOH IRU WKH SD PHQW RI GDPDJHV OO ULJKWV UHVHUYHG LQ WKH HYHQW RI WKH JUDQW RI D SDWHQW XWLOLW PRGHO RU RUQDPHQWDO GHVLJQ...

Страница 24: ... KWWS JODPR FRP JPR 7KH FRS LQJ GLVWULEXWLRQ DQG XWLOL DWLRQ RI WKLV GRFXPHQW DV ZHOO DV WKH FRPPXQLFDWLRQ RI LWV FRQWHQWV WR RWKHUV ZLWKRXW H SUHVVHG DXWKRUL DWLRQ LV SURKLELWHG 2IIHQGHUV ZLOO EH KHOG OLDEOH IRU WKH SD PHQW RI GDPDJHV OO ULJKWV UHVHUYHG LQ WKH HYHQW RI WKH JUDQW RI D SDWHQW XWLOLW PRGHO RU RUQDPHQWDO GHVLJQ UHJLVWUDWLRQ HLWHUJDEH VRZLH 9HUYLHOIlOWLJXQJ GLHVHV RNXPHQWV 9HUZHUWXQJ ...

Страница 25: ...25 4 4 Wiring Searchlight XS 2000 with Power supply N3 80E ...

Страница 26: ...26 4 5 Wiring R5 XS1000 with external PSU PX 50N ...

Страница 27: ...27 4 6 Wiring Main panel with focus ...

Страница 28: ...PDJHV OO ULJKWV UHVHUYHG LQ WKH HYHQW RI WKH JUDQW RI D SDWHQW XWLOLW PRGHO RU RUQDPHQWDO GHVLJQ UHJLVWUDWLRQ HLWHUJDEH VRZLH 9HUYLHOIlOWLJXQJ GLHVHV RNXPHQWV 9HUZHUWXQJ XQG 0LWWHLOXQJ VHLQHV QKDOWHV VLQG YHUERWHQ VRZHLW QLFKW DXV GU FNOLFK JHVWDWWHW XZLGHUKDQGOXQJHQ YHUSIOLFKWHQ X 6FKDGHQ HUVDW OOH 5HFKWH I U GHQ DOO GHU 3DWHQW HEUDXFKVPXVWHU RGHU HVFKPDFNVPXVWHUHLQWUDJXQJ YRUEHKDOWHQ QVFKOX 368 ...

Страница 29: ...RRCRĕ T 0PMHCIQHMLQKCR 5RE TC PR LP 6 2 0MUCPĕ08 2 ĕ ĕ ĕ ĕ 6ĕ ĕ ĕ X 3CRĕRFCĕPGEFRĕQUGRAFĕRMĕ 3CRĕRFCĕJCDRĕQUGRAFĕRMĕ LBĕRSPLĕRFCĕJGEFRĕML 4FCLĕKCQQSPCĕRFCĕASPPCLRĕUGRFĕ Lĕ KKCRCP BHSQRĕPGEFRĕQUGRAFĕSLRGJĕWMSĕPC AFĕ 7 0ĕK V ĕK V ĕ LGR GPCAR MLRPMJ BPU ĕ 2 ĕ 8 7 7 0 2 08 2 ĕ 054 0 0 53 7 4 5 qK 4 8 Power supply PX 50N for 1000W ...

Страница 30: ...H FRS LQJ GLVWULEXWLRQ DQG XWLOL DWLRQ RI WKLV GRFXPHQW DV ZHOO DV WKH FRPPXQLFDWLRQ RI LWV FRQWHQWV WR RWKHUV ZLWKRXW H SUHVVHG DXWKRUL DWLRQ LV SURKLELWHG 2IIHQGHUV ZLOO EH KHOG OLDEOH IRU WKH SD PHQW RI GDPDJHV OO ULJKWV UHVHUYHG LQ WKH HYHQW RI WKH JUDQW RI D SDWHQW XWLOLW PRGHO RU RUQDPHQWDO GHVLJQ UHJLVWUDWLRQ HLWHUJDEH VRZLH 9HUYLHOIlOWLJXQJ GLHVHV RNXPHQWV 9HUZHUWXQJ XQG 0LWWHLOXQJ VHLQHV ...

Страница 31: ...31 4 10 Power supply EX 100 D 1 for 2000 3000W ...

Страница 32: ...vals not exceeding 6 months Visual inspection of gasket and glands Control of all screws and nut connections Check the level of grease and refill when needed in glider for lamp holder Reflector and front glass to be cleaned with a soft cloth and ethanol or simular 1 year Fill up the grease niple on the top of the motorhus with a grease gun 3 year Tighten all terminal strips in the searchlight junc...

Страница 33: ...s no 402018 1009261 4 Lamp holder kit from series no 402019 1009189 5 Focus unit 2008153 2008153 6 Drum complete 1009303 1009304 7 Forks 1009314 1009313 8 Manouver fork 1009383 1009382 9 Seal kit drum 1009245 1009308 10 Cable kit drum 1009318 1009319 11 Cable external 1009344 1009345 12 Heat element drum 115V 1009135 on request Heat element drum 230V 1009173 1009118 13 Ignitor 1009348 1009349 14 E...

Страница 34: ...he bracket If this have been loosened or adjusted it is important that the lamp has approximate 1 to 1 5mm of free running space See the picture on part number 12 in this document 1 Turn off the fuse to the power supply rectifier and make sure nobody can turn it on during the replacement of the lamp Allow the lamp to cool down Use safety equipment Face cover and Gloves and are a minimum Caution Bec...

Страница 35: ...older from the bracket when doing a normal bulb change If this have been loosened or adjusted it is important that the light bulb has approximate 1 to 1 5mm of free running space because it is expanding when warm Check this by pushing the bulb backwards in the lamp holder using light force the spring holder in the back shall give you the necessary space when installed correctly 8 Unscrew the lamp ...

Страница 36: ...During operation it emits intense UV radiation which is harmful to the eyes and skin Keep light beam and hot components away from from flammable materials 15 Disposal Read attached operating instruction for the lamp ...

Страница 37: ... that the current limitation is bypassed The light does not turn on Check on the lamp that it get the ignition spark if no spark change the ignitor Check the lamp if the glass is white or black it is broken and have to be replaced Check that the power supply is on and switch for remote controll is Off only 2000W Check fuses on the power supply Focus does not work Control that limitswitches is worki...

Страница 38: ...orrect or negligent use or storing of the Products faulty assembly and or faulty installation including defects result ing from faulty modification work or repair of the Products initiated by the Purchaser or third parties without the prior written approval of the Supplier Further the Supplier shall not be liable for de fects in the Products caused by natural wear and tear The Supplier shall at it...

Страница 39: ...39 GLAMOX Production GmbH Co KG Glasower Weg 5 17166 Teterow Germany www glamox com gmo XS_R5 Xen Doc 7SL5002001 Rev 16 DCN 23339 Date 2020 03 24 ...

Отзывы: