14
For 1600-2000W
N3-80E
These high quality recti
fi
er power supplies have been expressly designed to ensure the correct
operation and long life of short arc Xenon lamps.
These units, developed to meet the recommendations of Xenon lamp manufacturers, are
fi
tted
with special IREM transformers with adjustable magnetic shunt for continuous output regulation
over the entire operating range.
The new and peculiar design guarantees a low acoustical noise, i.e. less than 55dB(A).
The special design, including an auxiliary
fi
lter unit, ensures a low ripple with a negligible starting
energy. Weight 105kg.
Further instructions in Installation guide for Recti
fi
er see page 30.
Adjust
current
by
turning
hand wheel.
Current
applied
to the lamp
should be
for.
A:320 mm
B:380 mm
H:770 mm
Electric installation
The main operation panel requires 24V DC connected in series with a 3A slow fuse
to the positive (+) conductor.
• The switch requires 24V DC in addition to grounding.
• Depending on the searchlight model it requires 115V AC or 230V AC.
• Power supplied to the power supply unit must be 3-phase and PE.
• Current supplied to the lamp unit must be speci
fi
c, (see Technical data for speci
fi
c type Omron).
Lamp set-point see page 30.
*To be able to turn o
ff
the searchlight from the main panel, the switch on top of the power supply
N3-80 must be in position “0” (Zero).
Note: Disconnect the power when working on the equipment!
Electrical equipment must be installed by authorized personnel!
Check the polarity when connecting 24V DC!
All searchlight system equipment MUST BE connected to ground/earth!
*
Содержание 4036538577789
Страница 1: ...1 INSTALLATION USER MANUAL SEARCHLIGHTS XENON SL40 R5 ...
Страница 10: ...10 2 3 Cut out main slave panel Hole dimensions for installing main panel ...
Страница 17: ...17 3 1 Program menu Parameter setting Example for 3000W Xenon ...
Страница 18: ...18 3 2 Program menu Parameter setting ...
Страница 20: ...20 3 4 Program menu Parameter mode setting ...
Страница 25: ...25 4 4 Wiring Searchlight XS 2000 with Power supply N3 80E ...
Страница 26: ...26 4 5 Wiring R5 XS1000 with external PSU PX 50N ...
Страница 27: ...27 4 6 Wiring Main panel with focus ...
Страница 31: ...31 4 10 Power supply EX 100 D 1 for 2000 3000W ...