![NORSELIGHT 4036538577789 Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/norselight/4036538577789/4036538577789_installation-and-user-manual_1705639037.webp)
37
5.3 Troubleshooting
Searchlight don ’t move , horizontal or vertical:
Check that there is no obstructions eg. stucked cable .
Open the lid on motor house and check the red warning lamps on the PCB.
If the light is red (and the searchlight is not in end position) on one of the lamps it can be
caused by the actual motor or the gear.
24V can be connected directly to the motor for testing. (Be aware that the current limitation is
bypassed)
The light does not turn on:
Check on the lamp that it get the ignition spark, if no spark change the ignitor
Check the lamp, if the glass is white or black it is broken and have to be replaced
Check that the power supply is on and switch for remote controll is O
ff
(only 2000W)
Check fuses on the power-supply
Focus does not work:
Control that limitswitches is working (with ohm-meter) see page 15-16
Check that there is enough grease on the moving parts
Check for alarm lamp inside the motorhouse on the Motor DriverCard, red means that the
motor is blocked.
Содержание 4036538577789
Страница 1: ...1 INSTALLATION USER MANUAL SEARCHLIGHTS XENON SL40 R5 ...
Страница 10: ...10 2 3 Cut out main slave panel Hole dimensions for installing main panel ...
Страница 17: ...17 3 1 Program menu Parameter setting Example for 3000W Xenon ...
Страница 18: ...18 3 2 Program menu Parameter setting ...
Страница 20: ...20 3 4 Program menu Parameter mode setting ...
Страница 25: ...25 4 4 Wiring Searchlight XS 2000 with Power supply N3 80E ...
Страница 26: ...26 4 5 Wiring R5 XS1000 with external PSU PX 50N ...
Страница 27: ...27 4 6 Wiring Main panel with focus ...
Страница 31: ...31 4 10 Power supply EX 100 D 1 for 2000 3000W ...