background image

E-644 (LHT0096)
E-645 (LHT0097)
E-646 (LHT0098)

SECURITY FLOODLIGHT

INSTALLATION MANUAL

Содержание E-644

Страница 1: ...E 644 LHT0096 E 645 LHT0097 E 646 LHT0098 SECURITY FLOODLIGHT INSTALLATION MANUAL ...

Страница 2: ...Less sensitive More sensitive TOP VIEW 120º SIDE VIEW 12m 2 5m A B D Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection C Lux Time ...

Страница 3: ...N CONDITION THAT The product has been bought by the user The product has not been misused or handled carelessly installed incorrectly or used on a voltage supply other than that shown on it Repairs have not been attempted by anyone other than SIMX LTD or their appointed agent This guarantee excludes liability for discolouration of paint or plastic or any user replaceable parts and in particular la...

Страница 4: ...he motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body needs to cross enter one of these zones to activate the sensor The best all round coverage is achieved with the unit mounted at the optimum height of 2 5m Careful positioning of the sensor will be required to ensure optimum performance See diagram A detailing dete...

Страница 5: ...es Insert the raw plugs into the holes IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation CONNECTION Wiring connections should be made directly into the unit s wiring 1 Remove the backplate by unscrewing the two retaining screws 2 Pass the cable through the entry grommet and secure under th...

Страница 6: ...sh the detection pattern If the detection area is too small for your requirements try angling the sensor head up Angling the head downwards will reduce the detection area should a smaller range be required When walk test are complete the unit will switch into Sensor Control Mode Simply cease movement within the detection area for approximately 60 seconds ensure the lamp is not illuminated The unit...

Страница 7: ...IDE MODE The light can be switched on for longer time periods by use of the Manual Override Mode This can be activated at night by using the internal wall switch or circuit breaker Switch the internal wall switch circuit breaker twice off on off on within 2 seconds The unit will now illuminate continuously until dawn or until switched back into Auto Mode To switch the unit back into Auto Mode flic...

Страница 8: ...detection of cars people using public thoroughfares adjacent to your property Check that the power is switched ON at the circuit breaker internal wall switch Turn OFF the power to the unit and check the wiring connections as per the diagram see previous section 3 Ensure no connections are loose Check the lamp If the lamp has failed replace Ensure that the lamp is seated correctly in the lampholder...

Страница 9: ...E G F H ...

Отзывы: