44
Quick Connect
Chapter 4. – Installation
Connecting the Quick Connect Cable to the two units.
1. Turn off the power.
2. Remove the front covers for both of the heaters (4 screws each)
3. Pass the Quick Connect Cord through the wiring throughway at the bottom of the units.
4. Plug the wire connector into the ‘Circuit Board’ connector inside both units.
5. Replace the front covers.
6. Turn on the power.
※
All units must be set to the same settings listed below before using in the Quick Connect Multi System.
1. Set ‘on’ at [6:QC] in Installer Mode. (Refer to below)
2. Set Clock. (Refer to page 35 in the Installation Manual)
3. Set Recirculation Timer, if recirculation is used. (Please refer to pages 19 ~ 24 in the Owner’s Guide)
<Note>
CA:01(Master) unit will be able to set as first setting ‘on’ at [6:QC] in Installer Mode.
Other unit will be automatically set CA:02(Slave) as second setting ‘on’ at [6:QC] in Installer Mode.
1. Turn off the power to the control panel. Press and hold the
‘Function Button’ for approximately 5 seconds to get into the
‘Installer Mode’.
Index
Parameter
Description
Quick connect mode : Master water heater
If ‘Quick connect mode’ is activated, [CA01]/[CA02]
appears on the display screen..
Quick connect mode : Slave water heater
<Note>
Auto (Self Learning Mode) Recirculation function is not available with the Quick Connect Systems.
2. Turn the dial button to ‘[6:QC]’
3. Press the ‘Dial Button’, the ‘oFF’ will now be
flashing.
5. Press the ‘Dial Button’ to store the current setting and
return back to ‘Installer Mode’.
4. Turn the ‘Dial Button’ clockwise to select ‘on’ in order
to activate Quick Connect Multi System function.