30
Table 10. M1/M5 Furnace Specifi cations - Factory Settings
Furnace
Model No
Input
MBtu/h
Output
MBtu/h
Orifi ce No
E.S.P.
In WC
Oil
Nozzle
Ignitor
Direct
Comb.
Blower
Motor
Hp
A/C Ready
Tons
Nat.
LP
M1MB 056
56
46
29
45
0.3
x
x
1/4
3
M1MC 056
56
46
29
45
0.3
x
x
1/2
4
M1MB 070
70
57
24
42
0.3
x
x
1/4
3
M1MC 070
70
57
24
42
0.3
x
x
1/2
4
M1MB 077
77
62
21
40
0.3
x
x
1/4
3
M1MC 077
77
62
21
40
0.3
x
x
1/2
4
M1MB 090
90
72
17
36
0.3
x
x
1/4
3
M1MC 090
90
72
17
36
0.3
x
x
1/2
4
M1BB 066
66
53
26
43
0.3
x
x
1/4
3
M1BC 066
66
53
26
43
0.3
x
x
1/2
4
M1BB 086
86
68
18
37
0.3
x
x
1/4
3
M1BC 086
86
68
18
37
0.3
x
x
1/2
4
M5SB 066
66
56
0.3
.50 Gph
x
Burner Model:
AF-10
1/4
3
M5SC 066
66
56
0.3
.50 Gph
x
1/2
4
M5SB 086
86
73
0.3
.65 Gph
x
Spray Angle:
80° A
1/4
3
M5SC 086
86
73
0.3
.65 Gph
x
1/2
4
NOTES:
• Electrical Supply - 120 volts, 60HZ, 1 Ph. Fuse or Breaker - 15 amps
• Temperature Rise - 45° F to 75° F
• High Altitude - See Table 11 (page 32). For Canadian Altitudes
(2,000’ to 4,500’), reduce the gas manifold pressure to 3.0” W.C.
for natural gas and to 8” W.C. for LP gas.
• Thermostat Circuit - 24 volts, 60HZ, 30 vac
• Normal Anticipator Setting - 0.4
• Manifold Pressure - Natural Gas: 3.5” w.c.
LP Gas: 10” w.c.