Operation
4-4
Part 1611362
−
01
E
2018 Nordson Corporation
Alarm Screen
Date/Time
Alarm banner
Exit
Alarm message
Navigation
Alarm silence
Acknowledged time
Alarm Screen
Alarm Message
Alarm Description
Alarm Banner
E_StopRelayDeEnergized
E-Stop on the door of the
enclosure for the feed center
has been pressed. Determine
reason and then reset by
twisting and releasing.
E-Stop Relay DeEngergized
LevelProbeSignalError
One or more of the powder
level sensors in the hopper are
not functioning properly. Check
sensor connections, mounting,
and sensing face.
Level Probe Signaling Error
LowPowderInHopper
Low powder sensor level is not
sensing powder. Check source
of powder (bulk unloader or
box) to verify transfer pumps
are functioning properly.
Low Powder in Hopper
UltrasonicSieveCommandError
Ultrasonic controller is not
functioning properly, so powder
will not sieve through screen.
Transfer of powder is halted.
Ultrasonic Sieve Not Responding
VirginTableVibratorTrip
Table vibrator motor starter has
sensed an overload condition
and will not operate.
Table Vibrator Failure
Содержание Spectrum VT Feed Center
Страница 4: ...Change Record ii Part 1611362 01 E 2018 Nordson Corporation...
Страница 8: ...Table of Contents vi Part 1611362 01 E 2018 Nordson Corporation...
Страница 12: ...Safety 1 4 Part 1611362 01 E 2018 Nordson Corporation...
Страница 24: ...Description 2 12 Part 1611362 01 E 2018 Nordson Corporation...
Страница 52: ...Operation 4 24 Part 1611362 01 E 2018 Nordson Corporation...
Страница 64: ...Troubleshooting 6 10 Part 1611362 01 E 2018 Nordson Corporation...
Страница 86: ...Repair 7 22 Part 1611362 01 E 2018 Nordson Corporation...
Страница 90: ...Parts 8 4 Part 1611362 01 E 2018 Nordson Corporation Hopper 10014043 4 5 7 8 6 1 2 3 Figure 8 2 Controller...
Страница 100: ...Diagrams 9 2 Part 1611362 01 E 2018 Nordson Corporation...
Страница 101: ......
Страница 102: ......
Страница 103: ......
Страница 104: ......
Страница 105: ......