Repair
7-18
Part 1611362
−
01
E
2018 Nordson Corporation
Hopper
Level Sensors
1. Remove the cable from the sensor.
2. Remove the damaged sensor.
3. Thread in the new sensor, ensuring there are 1 or 2 threads into the
hopper.
4. Re-install the cable to the sensor.
5. Place hand in front of sensor to ensure the controller screen reads the
sensor.
PD19386
Sensors
Figure 7-20 Level Sensors
Sieve Screen
1. Open the control panel and shut off the generator.
2. Disengage the lid latch and open the lid.
3. Remove the damaged sieve from the hopper.
4. Disconnect the converter.
5. Connect the converter to the new sieve screen.
6. Place the sieve screen back in the hopper.
7. Close and lock lid by engaging the lid latch.