Troubleshooting
6-7
Part 1611362
−
01
E
2018 Nordson Corporation
Corrective Action
Possible Cause
Problem
22. Feed center low
powder level alarm on
Alarm delay timer has run out,
level sensor not detecting powder
Alarm timer starts when the transfer
pump turns on. If the timer runs out
and the level sensor has still not
detected powder then the alarm is
turned on. The timer default is
3 minutes.
Problem with powder supply or
Fresh powder transfer pump
Refer to
Problems
related to powder,
sieve, or .
23. Color change does
not start
E
−
Stop button pressed
Reset E
−
Stop button.
Afterfilter exhaust fan not running,
or fan interlock circuit defective
Turn on exhaust fan. Check fan
interlock wiring between feed center
panel and main system panel.
PLC not initiating color change
sequence.
Check PLC operation. Contact your
Nordson representative or technical
support center for help.
Parts still in booth
Control system tracks parts through
booth and will delay color change
start until parts clear booth. Booth
length is configurable through Control
Configuration. Refer to Control
Operator Interface manual for more
information.
Control gun positioners not in
manual or auto mode
Set the gun positioners to either
manual or auto mode.
Control gun positioner #1
controller did not receive Color
Change start signal from feed
center
The feed center passes signals for
color change to the gun positioner #1
electrical panel which then
communicates with the Control
system.
Check the wiring and connections
between the feed center control
panel and the gun positioner #1
panel.
Reciprocator not in auto mode
Reciprocator must be in auto mode
for color change cycle to start.
Set the reciprocator to auto mode.
Continued...
Содержание Spectrum VT Feed Center
Страница 4: ...Change Record ii Part 1611362 01 E 2018 Nordson Corporation...
Страница 8: ...Table of Contents vi Part 1611362 01 E 2018 Nordson Corporation...
Страница 12: ...Safety 1 4 Part 1611362 01 E 2018 Nordson Corporation...
Страница 24: ...Description 2 12 Part 1611362 01 E 2018 Nordson Corporation...
Страница 52: ...Operation 4 24 Part 1611362 01 E 2018 Nordson Corporation...
Страница 64: ...Troubleshooting 6 10 Part 1611362 01 E 2018 Nordson Corporation...
Страница 86: ...Repair 7 22 Part 1611362 01 E 2018 Nordson Corporation...
Страница 90: ...Parts 8 4 Part 1611362 01 E 2018 Nordson Corporation Hopper 10014043 4 5 7 8 6 1 2 3 Figure 8 2 Controller...
Страница 100: ...Diagrams 9 2 Part 1611362 01 E 2018 Nordson Corporation...
Страница 101: ......
Страница 102: ......
Страница 103: ......
Страница 104: ......
Страница 105: ......