Repair
7-16
Part 1611362
−
01
E
2018 Nordson Corporation
Blanking Plate Installation
NOTE:
Clean the blanking plate (2) with isopropyl alcohol before applying
the gasket (1). The gasket alignment is not symmetrical.
1. Insert the bushing (5) into the pump port.
2. Align the appropriate blanking plate (2) with the ports on the pump
manifold.
NOTE:
There is a 1-pump and a 2-pump blanking plate depending on
the configuration of the assembly.
3. Insert the 65-mm button head cap screw (4) through the top of the
blanking plate.
4. From the bottom side of the pump manifold, the washer (6) slides onto
the 65-mm button head cap screw (4) and then the nut (7).
5. Using a 5-mm Allen wrench, insert the 25-mm button head cap screw
(3) into the threaded pump port.
NOTE:
The manifold seal (8), Nordson part 1608597, comes pre-installed.
If there is a need to replace the seal, apply adhesive to a syringe or Q-tip
and securely set the seal in the manifold port.
2
1
5
6
7
4
3
4
6
7
8
Installing Blanking Plate
Siphon Block Pump Manifold Section View
Figure 7-18 Blanking Plate Installation
Содержание Spectrum VT Feed Center
Страница 4: ...Change Record ii Part 1611362 01 E 2018 Nordson Corporation...
Страница 8: ...Table of Contents vi Part 1611362 01 E 2018 Nordson Corporation...
Страница 12: ...Safety 1 4 Part 1611362 01 E 2018 Nordson Corporation...
Страница 24: ...Description 2 12 Part 1611362 01 E 2018 Nordson Corporation...
Страница 52: ...Operation 4 24 Part 1611362 01 E 2018 Nordson Corporation...
Страница 64: ...Troubleshooting 6 10 Part 1611362 01 E 2018 Nordson Corporation...
Страница 86: ...Repair 7 22 Part 1611362 01 E 2018 Nordson Corporation...
Страница 90: ...Parts 8 4 Part 1611362 01 E 2018 Nordson Corporation Hopper 10014043 4 5 7 8 6 1 2 3 Figure 8 2 Controller...
Страница 100: ...Diagrams 9 2 Part 1611362 01 E 2018 Nordson Corporation...
Страница 101: ......
Страница 102: ......
Страница 103: ......
Страница 104: ......
Страница 105: ......