Repair
7-2
Part 334598G03
E
2008 Nordson Corporation
Tools/Supplies Required
Before beginning any of the repair tasks described in this section, make
sure you have the following tools and supplies:
S
See Figure 7-1: Combination tool provided with your spray gun
S
5
/
32
-in. hex wrench
S
Small flat-blade screwdriver
S
Phillips-head screwdriver
S
Service kits and replacement parts
S
Removeable threadlocking adhesive
S
Dielectric grease
S
PTFE grease lubricant (MagnaLube
r
G) or equivalant PTFE-based
lubricant
NOTE:
Refer to the
Parts
section for service kits and replacement parts.
A
B
C
D
Figure 7-1
Combination Tool
A. Screwdriver
B. Packing cartridge tool
C. Fluid tip tool
D. Hose tool
Nozzle, Restrictor, and Fluid Tip Replacement
See Figure 7-2.
1. Turn off the gun control unit and ground the spray gun electrode to
remove any residual charge.
2. Flush the fluid-delivery system, hoses, and spray gun.
3. Turn off the fluid-delivery system. Relieve system fluid pressures. Point
the spray gun into the booth or grounded container and activate it to
relieve any residual pressure.
4. Disconnect the fluid hose from the spray gun. Move the spray gun to a
clean, dry, flat surface.
Содержание kinetix
Страница 6: ...Table of Contents iv Part 334598G03 E 2008 Nordson Corporation ...
Страница 12: ...Safety 1 6 Part 334598G03 E 2008 Nordson Corporation ...
Страница 24: ...Installation 3 8 Part 334598G03 E 2008 Nordson Corporation ...
Страница 34: ...Maintenance 5 6 Part 334598G03 E 2008 Nordson Corporation ...
Страница 60: ...Repair 7 20 Part 334598G03 E 2008 Nordson Corporation ...
Страница 70: ...Parts 8 10 Part 334598G03 E 2008 Nordson Corporation ...
Страница 75: ...Safety Note KINETIX TRILOGY ATEX Page 3 DOC13015B05 ...