![Nordson FoamMix Flex Скачать руководство пользователя страница 88](http://html1.mh-extra.com/html/nordson/foammix-flex/foammix-flex_customer-product-manual_1704341088.webp)
FoamMix Flex Foaming System
82
Part 1129048_01
E
2020
Nordson Corporation
Alarm Screen Messages
The tables depict the messages that appear on the touch screen panel in the
event of a system problem. These tables provide typical corrective actions
for each message type.
VDK Dispensing Module or Controller
System Alarm
Alarm Message
Alarm Category
Corrective Action
VDK Alarms
Last Changed Data is
Out of Range
Warning
Edit the last entered
data point and correct
the new data to be
within the operational
range
.
PLC Low Battery Alarm
Warning
Replace the PLC battery
VDK Low Pressure Fault
Fault
S
Check for VDK pump
rotation
S
Check Bulk
Unloader supply
system
S
Check for
disconnected hoses
or leaks
VDK High Pressure
Fault
Fault
S
Check that the
solenoid is opening
the applicator
S
Check solenoid air
pressure
S
Check for plugged
nozzle
VDK Drive 1 Fault
Fault
Check the servo drive
for an alarm indication.
Also, refer to the
Kollmorgen user manual
for additional
information.
Содержание FoamMix Flex
Страница 6: ...Table of Contents iv Part 1129048_01 E 2020 Nordson Corporation...
Страница 29: ...FoamMix Flex Foaming System 23 Part 1129048_01 E 2020 Nordson Corporation This page intentionally left blank...
Страница 63: ...FoamMix Flex Foaming System 57 Part 1129048_01 E 2020 Nordson Corporation This page intentionally left blank...
Страница 67: ...FoamMix Flex Foaming System 61 Part 1129048_01 E 2020 Nordson Corporation This page intentionally left blank...
Страница 93: ...FoamMix Flex Foaming System 87 Part 1129048_01 E 2020 Nordson Corporation This page intentionally left blank...
Страница 104: ...FoamMix Flex Foaming System 98 Part 1129048_01 E 2020 Nordson Corporation This page intentionally left blank...
Страница 105: ......
Страница 106: ......