Operation
4-18
Part 1032059B
E
2003 Nordson Corporation
Manual 41-DURABLUE-MA-02
To adjust the set-point temperature of an individual component
1. Press and hold the Tank, Hose, or Gun key for three seconds.
If the tank key was pressed, the left display indicates 1 (Flashing). If a
hose or gun key was pressed, the left display indicates the number of
the first sequential hose or gun (Flashing). The right display indicates
the current set-point temperature of the component indicated in the left
display.
2. Scroll the left display to the number of the desired component.
The right display indicates the current set-point temperature of the
component that you selected in the left display.
3. Press a right-display scroll key.
The right display flashes.
4. Use the right-display scroll keys to enter the set-point temperature
recommended by the manufacturer of the hot melt. Refer to the
technical data sheet provided by the manufacturer of the hot melt to
determine the optimal set-point temperature.
5. Do one of the following:
S
To register the new set-point temperature and then move on to
change the set-point temperature of the next sequential component,
press the left-display scroll key and then repeat steps 4 and 5.
S
To register the new set-point temperature and return to the automatic
scan mode, go to step 6.
6. Press any component key (tank, hose, or gun).
The selected component begins to heat or cool to its new
set-point temperature.
Содержание DuraBlue D10L
Страница 91: ...Troubleshooting 6 11 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 93: ...Troubleshooting 6 13 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 95: ...Troubleshooting 6 15 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 97: ...Troubleshooting 6 17 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 99: ...Troubleshooting 6 19 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 101: ...Troubleshooting 6 21 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 103: ...Troubleshooting 6 23 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 105: ...Troubleshooting 6 25 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 107: ...Troubleshooting 6 27 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 109: ...Troubleshooting 6 29 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 111: ...Troubleshooting 6 31 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 113: ...Troubleshooting 6 33 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 115: ...Troubleshooting 6 35 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 131: ...Parts 7 13 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...
Страница 136: ...Parts 7 18 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...
Страница 142: ...Technical Data 8 6 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...