Monitor Melter Faults
The melter alerts the operator to the faults listed in Table 4-2. Faults affect
the melter in one of three ways: the heaters turn off; the heaters remain on,
but the fault condition persists; or the melter stops functioning.
When a fault occurs, you must diagnose and correct the fault condition and
then place the melter back into operation. You can use the fault log to
determine the type, order, and relative time of the last ten faults.
Table 4-2 Melter Faults
Display
Code/Sub-code
Name
Affect on the
Melter
Cause
F1/None
RTD
Heaters turn off
The RTD for the component indicated has failed or
the component was disconnected from the melter.
F2/None
Under temperature
Heaters turn off
The actual temperature of the component
indicated has dropped below the under
temperature delta, which was set using
parameter 22.
F3/None
Over temperature
Heaters turn off
The actual temperature of the component
indicated has increased beyond the over
temperature delta, which was set using
parameter 21.
F4/1
RAM test
Melter stops functioning
Internal RAM failure
F4/2
Internal Clock time
Heaters remain on, but
fault condition persists
Internal clock failure
F4/4
Internal clock battery
backed RAM
Heaters remain on, but
fault condition persists
Battery-backed RAM failure
F4/5
Internal clock battery
Heaters remain on, but
fault condition persists
Battery-backed RAM battery dead
F4/6
Analog-to-digital
Melter stops functioning
RTD analog-to-digital converter failed
F4/7
Analog-to-digital
calibration
Melter stops functioning
RTD analog-to-digital converter could not be
calibrated
F4/8
Main board feedback
Melter stops functioning
Communication failure between main board and
CPU
F4/A
Thermostat
Melter stops functioning
Tank or pump thermostat is open
Содержание DuraBlue D10L
Страница 91: ...Troubleshooting 6 11 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 93: ...Troubleshooting 6 13 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 95: ...Troubleshooting 6 15 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 97: ...Troubleshooting 6 17 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 99: ...Troubleshooting 6 19 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 101: ...Troubleshooting 6 21 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 103: ...Troubleshooting 6 23 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 105: ...Troubleshooting 6 25 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 107: ...Troubleshooting 6 27 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 109: ...Troubleshooting 6 29 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 111: ...Troubleshooting 6 31 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 113: ...Troubleshooting 6 33 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 115: ...Troubleshooting 6 35 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Страница 131: ...Parts 7 13 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...
Страница 136: ...Parts 7 18 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...
Страница 142: ...Technical Data 8 6 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...