background image

DuraBlue Adhesive Melters

Models D4L, D10L, and D16L

Customer Product Manual

Part 1032059B

Issued 07/03

NORDSON CORPORATION 

 DULUTH, GEORGIA 

 USA

www.nordson.com

Содержание DuraBlue D10L

Страница 1: ...DuraBlue Adhesive Melters Models D4L D10L and D16L Customer Product Manual Part 1032059B Issued 07 03 NORDSON CORPORATION DULUTH GEORGIA USA www nordson com...

Страница 2: ...e Squirt Magnastatic MEG Meltex Microcoat MicroSet Millennium Mini Squirt Moist Cure Mountaingate MultiScan Nordson OmniScan OptiMix Package of Values Patternview Plasmod PluraFoam Porous Coat PowderG...

Страница 3: ...ctices 1 4 Operating Practices 1 4 Maintenance and Repair Practices 1 5 Equipment Safety Information 1 6 Equipment Shutdown 1 6 Relieving System Hydraulic Pressure 1 6 De energizing the System 1 6 Dis...

Страница 4: ...llation Kit 3 5 Customer Supplied Materials 3 5 Mounting the Melter 3 6 Connecting the Electrical Service 3 8 Connecting Hoses and Guns 3 10 Setting Up the Melter 3 12 Quick Setup 3 12 Operating Param...

Страница 5: ...er Key 4 20 Pump Key 4 20 Setup Key 4 21 Seven day Clock Key 4 21 Standby Key 4 22 Shutting Down the Melter 4 23 Maintenance 5 1 Relieving System Pressure 5 2 Cleaning the Melter 5 2 Replacing the Fil...

Страница 6: ...17 Pressure Gage Kit 7 17 Handgun Support Kit 7 17 Automatic Pressure Control 7 17 Technical Data 8 1 General Specifications 8 1 Electrical Specifications 8 2 Motor and Pump Specifications 8 2 Dimensi...

Страница 7: ...n this document can result in personal injury including death or damage to equipment or property Safety Alert Symbols The following safety alert symbol and signal words are used throughout this docume...

Страница 8: ...with governing regulations Contact the authority having jurisdiction for information S Maintain safety information including the safety labels affixed to the equipment in readable condition Instructi...

Страница 9: ...ndustry Safety Practices The following safety practices apply to the use of the equipment in the manner described in this document The information provided here is not meant to include all possible sa...

Страница 10: ...le power disconnects to isolate the equipment and all independently powered auxiliary devices from their power sources S Properly ground all equipment Contact your local building code enforcement agen...

Страница 11: ...parts S Read and comply with the manufacturer s instructions and the MSDS supplied with equipment cleaning compounds NOTE MSDSs for cleaning compounds that are sold by Nordson are available at www nor...

Страница 12: ...ure The levels of shut down are Relieving System Hydraulic Pressure Completely relieve system hydraulic pressure before breaking any hydraulic connection or seal Refer to the melter specific product m...

Страница 13: ...ignal wiring to the gun solenoid valve s 3 Reduce the air pressure to the gun solenoid valve s to zero then relieve the residual air pressure between the regulator and the gun General Safety Warnings...

Страница 14: ...r seal Failure to relieve the system hydraulic pressure can result in the uncontrolled release of hot melt or cold adhesive causing personal injury HM WARNING Molten material Wear eye or face protecti...

Страница 15: ...f the melter If contact can not be avoided wear heat protective gloves and clothing when working around heated equipment Failure to avoid contact with hot metal surfaces can result in personal injury...

Страница 16: ...the hot melt has cooled 3 Do NOT attempt to remove the solidified hot melt from your skin 4 In case of severe burns treat for shock 5 Seek expert medical attention immediately Give the MSDS for the ho...

Страница 17: ...labels and tags Table 1 2 Safety Labels and Tags Item Description 1 WARNING Hazardous voltage Disconnect all power supply connections before servicing 2 CAUTION Burn hazard Hot surfaces 3 WARNING Haz...

Страница 18: ...Safety 1 12 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 19: ...lters When necessary the reader is referred to the documentation supplied with other Nordson products or products supplied by third parties With the exception of tank capacity hose gun capacity and ex...

Страница 20: ...sized and laminated so that it can be kept with the melter on the production floor Product Resource CD The resource CD which is stored in the back of this manual contains an electronic version of this...

Страница 21: ...C 450 _F for 240 VAC melters or below 200 _C 400 _F for 120 VAC melters S Be used with compatible hot melt hoses and guns that are manufactured by Nordson Corporation S Be used in non explosive enviro...

Страница 22: ...heir operating temperature hereafter referred to as set point temperature by a pre set number of degrees Setup The setup mode is used to configure melter control options and features and to review sto...

Страница 23: ...d the location of key melter components 3 5 12 13 1 2 4 11 6 7 9 10 8 Figure 2 3 Key components 1 Electrical enclosure door 2 Control panel see Figure 2 4 3 Tank lid 4 Side panels 5 Tank 6 Hose gun re...

Страница 24: ...003 Nordson Corporation Manual 41 DURABLUE MA 02 1 3 6 2 0 201 5 7 4 Figure 2 4 Control panel 1 Fault LED 2 Ready LED 3 Component keys LEDs 4 Control switch 5 Right display and scroll keys 6 Left disp...

Страница 25: ...melter to automatically adjust adhesive output based on production requirements S Pressure gauge that provides a manifold hydraulic pressure reading S Footswitch that allows manual pump activation S A...

Страница 26: ...Introduction 2 8 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 27: ...ainer will also contain one or more hot melt hoses and guns The melter is shipped from the factory with an installation kit that contains components that must be assembled on the melter by the custome...

Страница 28: ...hot melt hoses and guns 6 Set up the melter to work with the manufacturing process 7 Install optional equipment 8 If used Connect a gun driver pattern controller or timer 9 Flush the melter 10 Adjust...

Страница 29: ...ired Clearance Item Description D10L D16L D4L A Width of melter at the outside of the mounting brackets 441 mm 17 36 in 334 mm 13 14 in B Clearance required between the melter and the nearest object i...

Страница 30: ...when servicing the melter can result in personal injury including death Other Considerations Consider the following additional factors when determining where to install the melter S The maximum dista...

Страница 31: ...lso contains a package of safety label overlays that are printed in variety of languages If required by local regulations the appropriate language overlay should be applied over the English version of...

Страница 32: ...s Refer to Section 8 Technical Data for the weight of the melter Refer to the technical data provided by the hot melt manufacturer for information about the volumetric weight of the hot melt To mount...

Страница 33: ...Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 Table 3 2 Comparison of DuraBlue Melter Dimensions with Other Melter Dimensions Dimension 3100 3400 3500 3700 3830 3930 LS10 LS20 KB10...

Страница 34: ...DuraBlue melters is 20 amp Refer to Table 3 3 for the maximum amperages of 200 240 volt melters NOTE DuraBlue melters with an attached power cable are not for use with residential electrical service...

Страница 35: ...Installation 3 9 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 36: ...lt hose for your manufacturing process refer to the latest edition of Nordson s hot melt dispensing equipment Replacement Parts Catalog or contact your Nordson representative S Connect hoses to any of...

Страница 37: ...r Power Requirements for information about how to calculate the power required by Nordson hot melt guns S Refer to the user s guide that is shipped with each gun for information about installing the g...

Страница 38: ...ready set up The factory setup can be modified at any time to suit your manufacturing process Quick Setup Table 3 4 describes the most commonly used operating parameters and their factory settings Rev...

Страница 39: ...been enabled by pressing the pump key Enabled 20 Temperature Units Sets the units of the temperature display to degrees Celsius C or to degrees Fahrenheit F C 21 Over Temperature Delta Sets the number...

Страница 40: ...o 26 Control heaters Seven day Clock 50 to 77 Configure the clock feature In addition to the ability to read and edit parameter values you can also review a log of the last ten changes that were made...

Страница 41: ...o step 5 5 Press a right display scroll key The right display flashes 6 Use the right display scroll keys to enter the desired numeric set point or control option into the right display Refer to Appen...

Страница 42: ..._C 110 _F 15 _C 25 _F 22 Under Temperature Delta 5 _C 10 _F to 60 _C 110 _F 25 _C 50 _F 23 Standby Delta 25 _C 50 _F to 190 _C 350 _F 50 _C 100 _F 26 Manual Standby Time 0 to 180 minutes 0 disabled S...

Страница 43: ...possible value by simultaneously pressing both of the right display scroll keys While in the setup mode if no key is pressed for two minutes the melter will return to the automatic scan mode You can a...

Страница 44: ...e set point temperature S Individual Component The set point temperature of the tank and each hose and gun is set individually Since most manufacturing processes will require the tank hoses and guns t...

Страница 45: ...turer of the hot melt Refer to the technical data sheet provided by the manufacturer of the hot melt to determine the optimal set point temperature 5 Press the Tank key Each component begins to heat o...

Страница 46: ...flashes in the left display 2 Press the left display scroll key to change the display to parameter 3 the change history log The following occurs S If the last change was to an editable parameter all...

Страница 47: ...vidual S Set point Hose Key 1 6 A single hose Individual S Set point Gun Key 1 6 A single gun Individual All Keys 0 All components Global Hose Key 0 All hoses Global by component Gun Key 0 All guns Gl...

Страница 48: ...ensure that the pressure control valve is set to low pressure Before using the melter for production it should be flushed to remove any residue left over from factory testing Flushing the melter is a...

Страница 49: ...components S Using the melter function keys S Shutting the melter down Most of the controls described in this section are located on the control panel Refer to Key Components in Section 2 Introductio...

Страница 50: ...The position of the tank and pump is fixed at 1 Hose and gun position numbers are automatically assigned based on the hose gun receptacle they are connected to For example the position numbers of a h...

Страница 51: ...a scoop to fill the tank with hot melt Never use your bare hands Using your bare hands to fill the tank may result in personal injury 1 Open the tank lid 2 Use a scoop to fill the tank with hot melt T...

Страница 52: ...grees The sequence of the automatic scan is tank each hose and gun pair and then back to the tank S Turns on the ready LED green when the tank and all of the hoses and guns are within 3 _C 5 _F of the...

Страница 53: ...s processor or main board Section 4 Monitor Melter Faults The appearance of F1 in the right display immediately after starting the melter indicates that a hose or gun cordset may be loose or disconne...

Страница 54: ...he identification of heated components Confirm that the Melter is Operating Correctly The ready LED turns on green when all of the heated components are within 3 _C 5 _F of their set point temperature...

Страница 55: ...sing Melter Function Keys Monitor Component Temperatures You can check the actual temperature of each heated component the tank and each hose and gun using the automatic scan mode or by manually selec...

Страница 56: ...croll the left display past the number of the last sequential component in a component group the number of the first sequential component in the next component group appears in the left display The me...

Страница 57: ...Operation 4 9 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 58: ...ent indicated has dropped below the under temperature delta which was set using parameter 22 F3 None Over temperature Heaters turn off The actual temperature of the component indicated has increased b...

Страница 59: ...fected component key tank hose or gun turns on to indicate the type of component that has or is failing 3 The right display indicates the type of fault F1 F2 or F3 4 The left display indicates as foll...

Страница 60: ...fatal The fault LED turns on for five seconds but the heaters and pump continue to operate normally Nonfatal faults only affect the internal clock Refer to Section 6 Troubleshooting for information ab...

Страница 61: ...ult condition still exists two minutes after pressing the clear reset key the fault LED will turn back on When an F1 fault code appears you can determine whether the fault was caused by an open or a s...

Страница 62: ...r Table 4 3 provides the meaning of each digit in the log entry Following the table are two example fault log entries 3 Press the right display scroll key to review each of the remaining nine log entr...

Страница 63: ...temperature To view the number of heater hours that have elapsed since a log entry was created simultaneously press both of the right display scroll keys The hours are indicated in the right display...

Страница 64: ...ould be connected to the receptacle 1 Refer to More About Heated Components earlier in this section for information about hose gun positions To adjust set point temperatures using the global method 1...

Страница 65: ...rent set point temperature of the hose or the gun 2 Scroll the left display to 0 The right display indicates all dashes 3 Press a right display scroll key The right display flashes 4 Use the right dis...

Страница 66: ...temperature of the component that you selected in the left display 3 Press a right display scroll key The right display flashes 4 Use the right display scroll keys to enter the set point temperature r...

Страница 67: ..._C 350 _F The factory set point temperature of all others components is zero degrees off When the units of temperature is set to degrees Celsius the minimum and maximum set point temperatures are 40 _...

Страница 68: ...manually turn the component heaters on and off Pressing the heater key overrides the control on or off of the heaters by the seven day clock feature The LED on the heater key illuminates when the heat...

Страница 69: ...used to keep the melter in the last condition dictated by the clock heaters on or off or standby When a clock schedule calls for the heaters to be on the heaters are regulated at their pre assigned se...

Страница 70: ...arameters takes the melter out of the standby mode If the melter was set up to use the manual standby timer parameter 26 pressing the standby key will place the melter in the standby mode for the peri...

Страница 71: ...02 Shutting Down the Melter Shut the melter down when it will not be used for an extended period of time To shut the melter down 1 Switch the melter off 2 Disable the guns as follows S Air operated gu...

Страница 72: ...Operation 4 24 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 73: ...ter stops operating or is operating incorrectly refer to Section 6 Troubleshooting for information about diagnosing common problems and performing corrective maintenance Table 5 1 Preventive Maintenan...

Страница 74: ...emoved in order to clean out the spilled hot melt WARNING Risk of electricution and fire Do not clean the melter with a direct stream of water or steam Use only water or an appropriate non flammable c...

Страница 75: ...Maintenance 5 3 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 Figure 5 1 Removing the exterior panels...

Страница 76: ...lter reaches the end of its service life it should be replaced The factors that determine the service life of the filter are S the type grade and purity of the solid form hot melt S the set point temp...

Страница 77: ...an 8 mm 5 16 inch hex head wrench or an adjustable wrench to loosen counterclockwise and then remove the filter 3 Properly dispose of the old filter 4 Confirm that the O ring on the new filter is in g...

Страница 78: ...dhesive and the new adhesive if applicable To clean the tank when changing hot melt 1 Operate the melter normally until the tank is empty 2 Press the Pump key to stop the pump 3 Allow the melter to he...

Страница 79: ...ng material and then reinstall it 2 Add the appropriate type and quantity of hot melt solvent to the tank 3 Disconnect a hose from a gun and direct the hose into a waste container 4 Close the pressure...

Страница 80: ...Maintenance 5 8 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 81: ...faults indications as well as comprehensive melter diagnostic information that is provided in flowchart format If you cannot resolve the problem using the troubleshooting flowchart contact your Nords...

Страница 82: ...mponent Replace RTD See flowchart T 2 F3 None Over temperature The actual temperature of the component indicated has increased beyond the over temperature delta which was set using parameter 21 Replac...

Страница 83: ...Troubleshooting 6 3 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 84: ...l the status of the pump enabled disabled running and the associated indication that is provided by the pump LED S Use activation of a remote input to control the motor S Use of parameter 8 Automatic...

Страница 85: ...Yes On N A Green Disabled Manual No Not active On Off Off Disabled Manual Yes Off On Off Off Disabled Manual Yes On Off Yellow Disabled Manual Yes On On Green Enabled Manual No Off On Off Off Enabled...

Страница 86: ...S Refer to information provided elsewhere in this manual S Replace a component S Contact Nordson Corporation for technical assistance To return your melter to service as quickly as possible the chart...

Страница 87: ...ow F5 F6 Pump heater 5 A 250 V fast acting 5 x 20 mm F7 F8 Hose gun 1 heaters 6 3 A 250 V 5 x 20 mm F9 F10 Hose gun 2 heaters 6 3 A 250 V 5 x 20 mm F11 F12 Motor power 6 3 A 250 V 5 x 20 mm Connection...

Страница 88: ...Troubleshooting 6 8 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 89: ...enoid 2 Gun Solenoid 1 J1 Figure 6 1 TP2 TP4 CPU Power green CPU F ailure red 4 75 5 25 VDC P N 1 0 2 6 6 6 2 Tank Heater Left and Right Thermostat Center Tank RTD Bottom right Main Board P N 1031200...

Страница 90: ...Troubleshooting 6 10 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 91: ...Troubleshooting 6 11 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...

Страница 92: ...Troubleshooting 6 12 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 93: ...Troubleshooting 6 13 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...

Страница 94: ...Troubleshooting 6 14 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 95: ...Troubleshooting 6 15 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...

Страница 96: ...Troubleshooting 6 16 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 97: ...Troubleshooting 6 17 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...

Страница 98: ...Troubleshooting 6 18 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 99: ...Troubleshooting 6 19 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...

Страница 100: ...Troubleshooting 6 20 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 101: ...Troubleshooting 6 21 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...

Страница 102: ...Troubleshooting 6 22 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 103: ...Troubleshooting 6 23 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...

Страница 104: ...Troubleshooting 6 24 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 105: ...Troubleshooting 6 25 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...

Страница 106: ...Troubleshooting 6 26 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 107: ...Troubleshooting 6 27 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...

Страница 108: ...Troubleshooting 6 28 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 109: ...Troubleshooting 6 29 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...

Страница 110: ...Troubleshooting 6 30 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 111: ...Troubleshooting 6 31 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...

Страница 112: ...Troubleshooting 6 32 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 113: ...Troubleshooting 6 33 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...

Страница 114: ...Troubleshooting 6 34 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 115: ...Troubleshooting 6 35 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...

Страница 116: ...Troubleshooting 6 36 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 117: ...Troubleshooting 6 37 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 1 2 Figure NO TAG 2 Opening the tank isolation valve 1 Open 2 Closed...

Страница 118: ...Troubleshooting 6 38 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 119: ...s in the parts column means the part cannot be ordered separately Description Provides the part name as well as its dimensions and other characteristics when appropriate Bullets in the description ind...

Страница 120: ...ront Panel Service Kits Figure 7 1 Front panel service kit parts Item Part Description Quantity Note 1031176 Service kit panel front D4L with tags 1 S Panel front 1 1031177 Service kit panel front D10...

Страница 121: ...Service kit board display central processing unit CPU A 1 S PCA display CPU 1 NS S Stand off hex M3 x 8 mm 6 NS S Washer lock M3 6 1031200 Board main with heat sink A B 2 S Board with heat sink 1 3 C...

Страница 122: ...use service kit parts Item Part Description Quantity Note 1031203 Service kit fuses main board 1 105419 S Fuse fast 10 A 250 VAC 1 4 x 11 4 in F1 F2 2 2 939955 S Fuse slow 2 A 250 VAC 5 x 20 mm F3 F4...

Страница 123: ...W 1 1031225 Service kit heater tank D4L A NS S Heater assembly 120 V 2 x 425 W 1 1031226 Service kit heater tank D4L A NS S Heater assembly 240 V 2 x 425 W 1 1031231 Service kit heater tank D10L D16L...

Страница 124: ...B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 Tank Strainer 1 Figure 7 4 Tank strainer Item Part Description Quantity Note 1 1028330 Strainer tank D4L 1 1 1028334 Strainer tank D10L 1 1 102833...

Страница 125: ...Melter P N Motor P N Pump P N Manifold P N Complete Drive Assembly P N 1026747 1031211 1031204 1031207 1031216 1026747 1026750 1031211 1031204 1031207 1031216 1026748 1031211 1031204 1031208 1031217...

Страница 126: ...031205 Service kit pump 7 8 cc rev 1 S Pump 1 2 1033445 S Key machine drive 3 16 x 70 in 7 8 cc pump 1 2 1033444 S Key machine drive 1 8 x 3 4 in 4 9 cc pump 1 3 S O ring 118 Viton 0 862 x 0 103 in 1...

Страница 127: ...NS S O ring Viton 0 750 x 0 938 x 0 094 1 NS S O ring 188 Viton 0 862 x 0 103 1 NS S O ring Viton 1 188 x 1 388 x 0 094 1 NS S Grease high temperature 0 50 oz 1 NS S Key machine drive 0 125 x 0 75 1 N...

Страница 128: ...Parts 7 10 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 Manifold Figure 7 6 Manifold service kit parts...

Страница 129: ...1 or 2 A 6 S Connector 90 degree 9 16 18 x 9 16 18 1 B NS S Grease high temperature 0 50 oz 1 1031221 Service kit valve pressure control 600 psi 7 S Valve PCV 600 psi 1 1031222 Service kit valve press...

Страница 130: ...d 1 4 hp motor service kit parts Item Part Description Quantity Note 1 1031211 Motor 1 6 hp with pigtail 86 rpm 1 NS 208276 S Capacitor 10 F 370 VAC 1 A 1 1031213 Motor 1 4 hp with pigtail 131 rpm 1 N...

Страница 131: ...Parts 7 13 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 132: ...Parts 7 14 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 Drive Assembly Complete Figure 7 8 1 4 and 1 6 hp drive assembly...

Страница 133: ...Viton 0 862 x 0 103 in 1 6 S O ring Viton 1 188 x 1 388 x 0 094 in 1 A 7 S O ring Viton 0 750 x 0 938 x 0 094 in 1 A 8 S Key machine 3 16 x 1 inch long 1 9 S Screw hex cap M8 x 90 304 stainless steel...

Страница 134: ...Tool chip removal Connaccy 1 S Strap ground wrist anti static 1 Air Control Kit Part Description Quantity 1030533 Kit air control Pressure Control Valve Knob Part Description Quantity 1034248 Kit kno...

Страница 135: ...support 1 S Washer flat M6 2 Pressure Gage Kit Part Description Quantity 1030537 Kit gage 1500 psi S Gage 1500 psi with chemical seal 1 S Tape roll 1 S Swivel 37 9 16 18 x 1 4 1 S Connector with O rin...

Страница 136: ...Parts 7 18 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 137: ...17 lb hr D16L 11 2 kg hr 24 7 lb hr 120 VAC D4L 4 7 kg hr 10 3 lb hr D10L 7 7 kg hr 17 0 lb hr D16L 6 1 kg hr 13 4 lb hr Noise 64dB A at maximum pump speed A Workplace temperature 0 to 50 C 32 to 120...

Страница 138: ...A IP rating IP 32 A NOTE A Flow setpoint at manifold outlet Motor and Pump Specifications Item Data Note Viscosity Range Melter with filter 1000 30000 cps Melter without filter 1000 10000 cps Maximum...

Страница 139: ...Technical Data 8 3 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 Dimensions D4L Melter Figure 8 1 D4L melter dimensions D10L and D16L Melter Figure 8 2 D10L D16L melter dimensions...

Страница 140: ...Technical Data 8 4 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 Figure 8 3 B900N mounting dimensions...

Страница 141: ...Technical Data 8 5 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 Conduit Penetration Sizes D10 D16 D4 Figure 8 4 Electrical enclosure conduit penetrations...

Страница 142: ...Technical Data 8 6 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 143: ...dispensed The following three maximum wattages must be considered when calculating melter power requirements S Single component maximum The wattage of any single hose or gun S Hose gun pair maximum Th...

Страница 144: ...the sum in Column C of Table A 1 5 Compare each of the wattages tabulated in Columns A B and C of Table A 1 with the associated maximum allowable wattages in Table A 2 for 240 VAC melters or Table A 3...

Страница 145: ...Column in Table A 1 Component Maximum Wattage A Any single hose or gun 1000 W B Any hose gun pair 1200 W C Sum of hose gun pairs 1 and 2 2000 W Table A 3 Maximum Allowable Hose Gun Wattages for 120 VA...

Страница 146: ...Calculating Melter Power Requirements A 4 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 147: ...t selecting and editing operating parameters refer to Section 3 Installation Setting Up the Melter NOTE Parameter numbers that are reserved or that are not used do not appear in this appendix Table B...

Страница 148: ...faults Value Resolution Default Value _ F0 unused log entry Format F1 F2 F3 and F4 Use Use the right display scroll keys to review the log entries for the last ten faults Empty log entries are indica...

Страница 149: ...right display at the end of every automatic scan cycle When the delay time reaches 1 minute the time remaining appears in seconds 7 Motor Off Delay Description Determines the amount of time the motor...

Страница 150: ...the electric gun manual for information on mounting and using the gun 13 Change Hose 2 Output to Electric Gun Activation Description Changes the proportioned 240 VAC current that is provided to the ho...

Страница 151: ...10 _F to 60 _C 110 _F Resolution 1_C 1_F Default Value 25 _C 50 _F Format Use 23 Standby Delta Description The number of degrees by which all heated components will be decreased when the applicator is...

Страница 152: ...lt Value 0 Format Use Set the standby time when you want the operator to be able to place the melter into the standby mode for a limited period of time break lunch etc When manual standby is enabled v...

Страница 153: ...Operating Parameters B 7 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02 This page intentionally left blank...

Страница 154: ...r and exit the standby mode 4 Using parameters 60 through 68 create schedules 2 and 3 by repeating step 3 5 Use parameters 71 through 77 to assign which of the four schedules should be used on each da...

Страница 155: ...aters on at 0700 and off at 1700 Monday through Friday and turn the heaters off Saturday and Sunday Par 55 0700 Par 56 1700 Par 57 Par 58 Par 71 through 75 1 Par 76 and 77 0 Example 3 To turn the heat...

Страница 156: ...se This setting only needs to be made once for all daily schedules 55 Schedule 1 Heaters On Description Used to set the time that the clock will turn on the heaters during schedule 1 Value 0000 to 235...

Страница 157: ...Used to set the time that the melter will exit the standby mode during schedule 1 Value 0000 to 2359 Resolution 1 minute Default Value Format Hour Hour Minute Minute Use Set the time that the applica...

Страница 158: ...schedule 2 To disable this parameter set the parameter s value to by simultaneously pressing both of the right display scroll keys Note Do not set an enter standby time that is outside of the time pe...

Страница 159: ...o 2359 Resolution 1 minute Default Value Format Hours Hour Minute Minute Use To disable this parameter set the parameter s value to by simultaneously pressing both of the right display scroll keys 67...

Страница 160: ...splay scroll keys Note Do not set an exit standby time that is outside of the time period defined by the schedule s heater on and off time The melter cannot enter the standby mode when the heaters are...

Страница 161: ...hedule s for the day NOTES If the 0 schedule option is used the heaters will not turn on again until the next scheduled heaters on time arrives 73 Schedules for Wednesday Description Used to select wh...

Страница 162: ...s the active schedule s for the day NOTES If the 0 schedule option is used the heaters will not turn on again until the next scheduled heaters on time arrives 75 Schedules for Friday Description Used...

Страница 163: ...e schedule s for the day NOTES If the 0 schedule option is used the heaters will not turn on again until the next scheduled heaters on time arrives 77 Schedules for Sunday Description Used to select w...

Страница 164: ...Description Used to change the preset PID selections Use parameter 80 to select the value for hose 1 parameter 81 to select the value for gun 1 and so on Value 0 Hose 1 Standard gun 2 Large gun 3 Air...

Отзывы: