Operation
4-1
E
1996 Nordson Corporation
All rights reserved
108 390B
Issued 7/96
Manual 10-10
Operation
WARNING:
Allow only qualified personnel to perform the
following tasks. Observe and follow the safety instructions in
this document and all other related documentation.
This section contains instructions for preparing, adjusting, operating, and
maintaining your Compact Manual Voltage-Block Iso-Flo system.
The lubricator must be filled with lubricant and the flow rate adjusted on
initial startup of the Compact Manual Iso-Flo system.
Nordson type Q solvent is normally used as a lubricant. It is shipped in
concentrated form and must be mixed with 10 gallons of water before
use. Refer to section 7 of this manual for the type Q solvent part number.
NOTE:
Do not use the mixing directions provided on the container label.
Failure to follow the proper mixing instructions (noted above) could cause
polymerization of the Q solvent concentrate, resulting in clogging of
components.
See Figure 4-1. Use the following steps when filling the lubricator and
adjusting its flow rate:
1. Unscrew the filler cap (1) from the top of the lubricator and fill the
lubricator.
2. Turn the flow-rate adjustment screw (2) counterclockwise until open.
3. Start the system and then adjust the lubricator so it delivers three to
five drops of lubricant for each spray cycle (between pump refills).
Use the lubricator sight glass (3) to monitor the flow rate.
NOTE:
When first filled, the lubricator may not prime itself and begin
delivering lubricant to the pump air for several operating cycles.
1. Introduction
2. Preparing the Lubrication
System
Preparing a Lubricant
Filling Lubricator and Adjusting
Flow Rate
Содержание Compact Manual Iso-Flo Voltage-Block
Страница 5: ...E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1 Section 1 Safety...
Страница 6: ...Safety 1 0 E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1...
Страница 20: ...Safety 1 14 E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1...
Страница 21: ...E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10 Section 2 Description...
Страница 22: ...Description 2 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Страница 30: ...Description 2 8 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Страница 31: ...E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10 Section 3 Installation...
Страница 32: ...Installation 3 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Страница 40: ...Installation 3 8 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Страница 41: ...E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10 Section 4 Operation...
Страница 42: ...Operation 4 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Страница 50: ...Operation 4 8 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Страница 51: ...E 1995 Nordson Corporation All rights reserved 108 390A Issued 10 95 Manual 10 10 Section 5 Troubleshooting...
Страница 52: ...Troubleshooting 5 0 E 1995 Nordson Corporation All rights reserved 108 390A Issued 10 95 Manual 10 10...
Страница 56: ...Troubleshooting 5 4 E 1995 Nordson Corporation All rights reserved 108 390A Issued 10 95 Manual 10 10...
Страница 57: ...E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10 Section 6 Repair...
Страница 58: ...Repair 6 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Страница 61: ...E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10 Section 7 Parts...
Страница 62: ...Parts 7 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...