Troubleshooting
5-3
E
1995 Nordson Corporation
All rights reserved
108 390A
Issued 10/95
Manual 10-10
Problem
Possible Cause
Corrective Action
5. Lubricator filter contains
coating material
Pump seals are worn, coating
material is leaking
Replace or repair pump seals.
6. Pump is making noise
Air is in fluid lines
Turn off electrostatic voltage, open
cabinet door, and trigger spray device
into the spray booth or a grounded
waste container to purge air.
7. Shuttle is not closing to
refill pump
Air is leaking from the atomizing air
hose or fittings
Repair or replace air hoses or fittings.
Make sure you use sealant on fitting
threads.
Door valve is malfunctioning
Turn off electrostatic voltage, open
cabinet door. Shuttle should close when
door is opened.
Sync valve is malfunctioning
Replace sync valve if it does not shift in
response to air pressure.
8. Shuttle is not
disengaging when spray
device is triggered
System air pressure is too low
Increase system air pressure.
Cabinet door is open
Close the cabinet door.
Cabinet door is not making contact
with door valve push-button
Make sure door valve push-button is
depressed when door is closed.
Pilot valve is malfunctioning
Replace valve if it does not shift in
response to air pressure in the line.
9. Shuttle couplings leaking
Dry female coupling shaft
Grease spring and shaft with O-Ring
lubricant and a stiff brush.
Male coupling ball and seat not
sealing due to contamination
Flush with cleaning solution.
Disassemble coupling and clean, if
necessary.
Dried coating material is on the
sealing surfaces of couplings
Clean couplings with a compatible
cleaning solution. If necessary,
disassemble couplings and clean.
Coupling O-rings damaged or out of
grooves
Disassemble couplings and repair.
2. Troubleshooting
Procedures
(contd.)
Содержание Compact Manual Iso-Flo Voltage-Block
Страница 5: ...E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1 Section 1 Safety...
Страница 6: ...Safety 1 0 E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1...
Страница 20: ...Safety 1 14 E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1...
Страница 21: ...E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10 Section 2 Description...
Страница 22: ...Description 2 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Страница 30: ...Description 2 8 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Страница 31: ...E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10 Section 3 Installation...
Страница 32: ...Installation 3 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Страница 40: ...Installation 3 8 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Страница 41: ...E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10 Section 4 Operation...
Страница 42: ...Operation 4 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Страница 50: ...Operation 4 8 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Страница 51: ...E 1995 Nordson Corporation All rights reserved 108 390A Issued 10 95 Manual 10 10 Section 5 Troubleshooting...
Страница 52: ...Troubleshooting 5 0 E 1995 Nordson Corporation All rights reserved 108 390A Issued 10 95 Manual 10 10...
Страница 56: ...Troubleshooting 5 4 E 1995 Nordson Corporation All rights reserved 108 390A Issued 10 95 Manual 10 10...
Страница 57: ...E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10 Section 6 Repair...
Страница 58: ...Repair 6 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Страница 61: ...E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10 Section 7 Parts...
Страница 62: ...Parts 7 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...