![Nordica LNK15 EVO Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/nordica/lnk15-evo/lnk15-evo_user-manual_1701827045.webp)
1
2
3
4
ENGLISH
smoKe
fan
The smoke fan is made up of two parts and is flanged to the boiler’s structure. fig. 12
attention
fan connecTed.
dIsconnecT The maIns PoWer suPPly!
fig. 12
: fan and smoke return
loosen the connection screws between the fan, gasket and smoke discharge.
carefully check ThaT no ashes or sooT have dePosITed onTo The fInned ImPeller of The fan. If necessary, clean WITh a
vacuum cleaner or a brush.
1
fan structure
2
fan gasket
3
fan motor
4
smoke discharge sensor
annual cleaninG
The following conditions must be ensured in order to execute annual cleaning of the boiler:
•
boiler moDe:
boiler in standby mode - off
•
boiler temperature below 30 °c
•
no voltage on the boiler - Turn the main switch from
i
to
o
, disconnect the mains power supply.
IT Is noT PossIble To execuTe cleanIng If The boIler Is noT In “sTandby mode - off”.
If the boiler is operating, it cannot be stopped (wait until combustion has ended automatically!).
attention
exTremely hIgh boIler TemPeraTures can cause burns/InJury!
attention
If The maIn sWITch Is noT enabled (boIler dIsconnecTed from PoWer suPPly), elecTrIcal shocks
are sTIll PossIble on lIve ParTs.
The ceramic stones can be removed from the lower combustion chamber during annual maintenance.
after cleaning, they must be pushed back against the rear wall of the lower combustion chamber of the boiler. (fig. 11)
fig. 11
: removal of the ceramic stones from the lower combustion chamber.
45