![Nordica LNK15 EVO Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/nordica/lnk15-evo/lnk15-evo_user-manual_1701827025.webp)
VSP
VST
95 °C
T
TS
CA
R
VMS
VM
VE
M
1
2
3
12
13
14
15
11
6
6
7
8
9
10
16
5
4
ENGLISH
1
lnk-evo reverse flame boiler
2
auTomaTIc
thermal DischarGe valve Dsa
3
safeTy valve
2.5 bar
4
ThermomeTer
5
Pressure gauge
6
exPansIon Tank
7
cIrculaTor
8
anTI-condensaTIon mIxIng valve for 60°c recIrculaTIon circuit
(can be supplied as an oPTIonal
accessory)
9
balancIng valve
10
Puffer
11
solar Panels
12
domesTIc hoT WaTer ProducTIon
13
auxIlIary boIler (gas, meThane, lPg or dIesel)
14
radIaTor sysTem (high temperature)
15
radIanT Panel sysTem (low temperature)
16 (*)
buffer tanK probe
(*)
ImPorTanT: The PosITIon of The buffer Tank Probe Is IndIcaTIve. The real PosITIon has To be evaluaTed WITh The InsTaller/
desIgner.
closeD vessel installation.
the DiaGrams are purely inDicative, therefore they Do not have DesiGn value
.
InsTallaTIon, relaTIve sysTem connecTIons, commIssIonIng and verIfIcaTIon of correcT oPeraTIon musT be carrIed ouT
correcTly by ProfessIonally QualIfIed and TraIned Personnel In full comPlIance WITh currenT naTIonal, regIonal,
ProvIncIal and munIcIPalITy regulaTIons In The counTry Where The aPPlIance Is InsTalled.
size the system correctly to avoid long pause times that would cause significant problems like the ones mentioned in the section regarding
doWn-fIred boIler oPeraTIon.
aTTenTIon: The boIler PumP Works on The basIs of The TemPeraTure dIfference beTWeen The boIler and The
buffer Tank. If The boIler TemPeraTure falls beloW The buffer Tank TemPeraTure, The PumP Is sWITched off.
25