electrical connection
all electrical connections can be made by qualified electricians only!
This goes for 230v connections in particular!
attention: risk of electric shock
The mains connection must be made in a workmanlike manner!
The boiler is delivered internally pre-wired.
If it was not necessary to loosen any connections when disassembling it, all the connections or plug connections are secured at the back of
the boiler.
(see photo marked in red)
mains connection plug (230v)
fine fuse 3.15a
fan connector output (230v)
boiler circuit pump plug (230v)
smoke sensor
buffer sensor
Potential-free contact
the proDuct must be installeD anD connecteD by qualifieD personnel in compliance with current reGulations.
(see chap. sPecIal WarnIngs).
norDica s.p.a. shall not be helD liable for unauthoriseD proDuct moDifications as
well as use of non-oriGinal spare parts.
warnIng
: the boIler must be connected to the maIns wIth an upstream dIfferentIal lIne
cut-off swItch accordIng to current regulatIons.
connect the power supply cable of the boIler to a bIpolar swItch wIth a mInImum dIstance
between contacts of 3mm (power supply 230 v~ 50 hz; correct system earthing is essential).
the power supply cable must be checked regularly and kept In Its orIgInal status. any type of
InterventIon on the safety cIrcuIts and sIngle elements Is forbIdden so as not to compromIse
safe and relIable operatIon of the boIler. In the event of damage to the electrIcal system, put
the boIler out of servIce, dIsconnect It from the power supply and ensure professIonal repaIr
Is carrIed out In complIance wIth current regulatIons.
attention: the power cable must not be in contact with hot parts.