sensore fumi
ENGLISH
boiler assembly
Disassembly / introDuction / assembly
The product is delivered almost completely pre-assembled. only the lever for cleaning the heat exchanger and the fan unit needs to be
installed.
Disassembly
depending on the conditions of the room in which the boiler is installed, some parts of it may be disassembled differently for transport
purposes.
weight reduction
:
- removal of suspended plates;
- removal of ceramic components and refractory panels from the upper and lower combustion chambers;
- disassembly of the covering door;
- disassembly of the three boiler doors;
please note
:
When disassembling components from inside the boiler, the disassembled parts must be marked in order to be able to install them quickly
and correctly.
hanDlinG
The boilers are screwed onto the transport pallets for safety reasons. loosen these screws and push the boiler off the pallet.
If the boiler needs to be lifted, there is an eyelet welded to the centre of it.
It is advisable to use a pallet truck when moving it at ground level.
any disassembly must be adapted to the conditions of the room as well as the type of installation, so that the boiler is not damaged!
assembly
If the boiler is installed as delivered, only the following precautions must be taken to complete the system:
- assembly and alignment of the adjustable feet;
- assembly of the components of the smoke exhaust system;
- assembly of the lever for cleaning the heat exchanger (description below).
positioning the smoke sensor
The smoke sensor is inserted in the dedicated hole above the flue flange and it is
locked in place by means of a self-tapping screw.
(see image to the side)
connectinG the smoKe exhaust system
The connection between the smoke exhaust and the chimney flue must be chosen according to the chimney calculation and the configurations
that the installation room allows.
it is necessary to take into account product and installation regulations.
The smoke exhaust system and relative gasket are not pre-assembled.
This unit can be installed at different angles depending on the installation site and the position of the chimney.
The possible variants, vertical and 45° to the right/left, are shown below.
smoke sensor