P2M054STD-Ver1.2
GB
Cleaning, Care & Maintenance
Routine maintenance
Switch OFF and disconnect from the power supply before cleaning.
Clean the enclosure and interior of the appliance as often as possible.
Blast chiller maintenance must include at least one daily cleaning of the loading zone to
prevent the development and accumulation of bacteria.
Before cleaning the chamber, perform a defrost cycle leaving the door open and removing
the drain plug.
Blast chiller defrosting cycle is performed in manual mode and can be performed with open
door
After the appliances finishes the blast chilling/freezing cycle, the drain plug of the waste
water must be removed so that the condensate water will flow into the tank. The drain pipe
also serves to drain out any liquids of the product.
At the end of each defrost cycle check the water level and if necessary empty the tray
(located underneath the unit).
Clean the unit with moist cloth. Never allow the switch, control panel, cable or plug to get wet.
Do not use abrasive cleaners, products containing chlorine, caustic soda, muriatic acid, vinegar
and chlorine bleach. These can leave harmful wastes. Use only neutral soap and water.
Clean the door seal with water only.
Ensure that no cleaning water penetrates into the electrical components.
Must not be cleaned by a water jet.
Always wipe dry after cleaning with soft cloth.
Do not allow water used in cleaning to run through the drain hole into the evaporation pan.
Take care when cleaning the rear of the appliance.
An agent or technician must carry out repairs if required.
If the appliance is to be left inactive for long periods, unplug the appliance after having turned
the switch to
OFF
position, empty the refrigerating compartment and clean thoroughly.
Blast chiller maintenance must include at least one daily cleaning of the temperature needle
probe.
It is recommended to deeply rinse the needle probe with clean water and a sanitizing solution
Special maintenance
The instructions given in the following paragraph can be followed from qualified technicians
Periodically clean the condenser using suitable tools (vacuum cleaner or soft brushes) can extend
the life of the appliance.
Check that the electrical connections are not loose.
Check that the thermostat and the sensor are in proper working order.
55
Содержание 45110250
Страница 1: ...Bedienungsanweisung COOL LINE Schnellkühler Schockfroster SKF 5 Easy Art 45110250 2019 12 ...
Страница 3: ...Produktbeschreibung Bezeichnung des Geräts Schockkühler 5 Trays GN und Euronorm 3 ...
Страница 27: ...Sonderzubehör Versetzen des Türanschlags 27 ...
Страница 28: ...Sonderzubehör 28 ...
Страница 33: ...Instruction Manual COOL LINE Blast Chiller SKF 5 Easy Art 45110250 33 ...
Страница 35: ...P2M054STD Ver1 2 GB Product Overview Article Description Blast Chiller N 5 Trays GN and Euronorm 35 ...
Страница 59: ...P2M054STD Ver1 2 GB Optional Accessory How to reverse the door 59 ...
Страница 60: ...P2M054STD Ver1 2 GB Optional Accessory 60 ...
Страница 65: ...Istruzioni d uso Abbattitore SKF 5 Easy Art 45110250 65 ...
Страница 67: ...P2M054STD Ver1 2 IT Panoramica Prodotto Descrizione articolo Abbattitore N 5 Teglie GN e Euronorm 67 ...
Страница 92: ...P2M054STD Ver1 2 IT Accessorio opzionale Come invertire la porta 92 ...
Страница 93: ...P2M054STD Ver1 2 IT Accessorio opzionale 93 ...