![background image](http://html.mh-extra.com/html/nordcap/45110250/45110250_instruction-manual_1701313043.webp)
P2M054STD-Ver1.2
GB
Operation
Blast chilling and freezing functionality
Blast Chilling and Freezing cycle have two main working option: controlled by temperature or by
time:
If operator chooses
TEMPERATURE
cycle option, temperature will be detected by
needle probe “
n2P”
and cycle will end once needle probe reaches the pre-setting
temperature according to value of parameter
+3°C
for chilling and
-18°C
for freezing. After
cycle ends the device will switch automatically to “
storage mode
” that will keep the
stored food at a pre-setting temperature: chilling
+2°C
; freezing
-20°C
until the storage
mode status will be ending by pressing “START/STOP” key.
During the temperature cycle the display will show always the value of needle probe
temperature “
n2P”
. Once storage cycle starts the display will show the value of chamber
temperature “
rNP”
.
Note
: End user can modify the pre-setting ending needle probe temperature: (AFTER
CYCLE SELECTION but BEFORE PRESS START/STOP key).
Press and release the
UP
or
DOWN
keys before start the cycle, the display will
show the set point of temperature meantime the “ “ icon start flashing. Then press
or keys to modify the set point and confirm the new parameter pushing key.
The modify value will be stored.
If end user don’t confirm the new value by key, the device will back to pre-setting
temperature value (
-18°C
) after
15s
.
If operator chooses
TIME
cycle option, temperature will be detected by chamber
probe “
rNP”
and thermostat display will show pre-setting time cycle of
120 Min.
for
chilling and
240 Min
. for freezing. Once chamber temperature reaches a pre-set value of
+3°C
for chilling and
-18°C
for freezing the compressor will stop. Cycle will end once the
pre-setting duration cycle time will reach
0 min
.
After ending cycle the device will enter in a “
storage mode
” that will keep the stored food
at pre- setting temperature according to the value of parameter: chilling
+2°C
; freezing
-
20°C
until the storage mode status will be ending by pressing “START/STOP” key.
During the time cycle the display will show time left to finish the cycle. Once storage cycle
starts the display will show the value of chamber temperature “
rNP”
.
Note
: End user can modify the pre-setting time as follow: (AFTER CYCLE SELCTION BUT
BEFORE PRESS START/STOP key).
Press and release the
UP
or
DOWN
keys before start the cycle, the display
will show the presetting time cycle in decimal unit (1 = 1min.) meantime the “ ”+ +
icons start flashing. Then press or keys to modify the time and confirm the new
time value pushing key.
The modify value will be stored.
If end user don’t confirm the new value by key, the device will back to pre-setting
time value (
120
min.) after
15s
.
43
Содержание 45110250
Страница 1: ...Bedienungsanweisung COOL LINE Schnellkühler Schockfroster SKF 5 Easy Art 45110250 2019 12 ...
Страница 3: ...Produktbeschreibung Bezeichnung des Geräts Schockkühler 5 Trays GN und Euronorm 3 ...
Страница 27: ...Sonderzubehör Versetzen des Türanschlags 27 ...
Страница 28: ...Sonderzubehör 28 ...
Страница 33: ...Instruction Manual COOL LINE Blast Chiller SKF 5 Easy Art 45110250 33 ...
Страница 35: ...P2M054STD Ver1 2 GB Product Overview Article Description Blast Chiller N 5 Trays GN and Euronorm 35 ...
Страница 59: ...P2M054STD Ver1 2 GB Optional Accessory How to reverse the door 59 ...
Страница 60: ...P2M054STD Ver1 2 GB Optional Accessory 60 ...
Страница 65: ...Istruzioni d uso Abbattitore SKF 5 Easy Art 45110250 65 ...
Страница 67: ...P2M054STD Ver1 2 IT Panoramica Prodotto Descrizione articolo Abbattitore N 5 Teglie GN e Euronorm 67 ...
Страница 92: ...P2M054STD Ver1 2 IT Accessorio opzionale Come invertire la porta 92 ...
Страница 93: ...P2M054STD Ver1 2 IT Accessorio opzionale 93 ...