P2M054STD-Ver1.2
GB
Operation
3.
Press and release START/STOP key to start freezing hard cycle: the Compressor LED
icon + plus , and needle probe led icon will switch
ON
permanently.
(Time cycle will be
ON
instead).
4.
Once the needle probe temperature reaches the pre-setting point or time cycle is ending,
a visual and acustic alarm will notify the ending cycle, the unit will start a storage cycle
and led icon will flashing.
Note
: During the storage cycle the display will show chamber temperature “
rNP”
.
Ice Cream cycle
Note
: Needle probe can not be used for the following steps (Temperature will be detected by
chamber probe
“rNP”
)
1.
Press and release
Ice cream
key, the , and led icons will start flashing, and
display will show
210Min
.
2.
Press one time START/STOP key, a pre-cooling cycle will be starting (
for 20min
.) and
once the internal temperature reach
-20°C
(
“rSP”
parameter value) the compressor will
stop, after
5min
. will restart and work for keep temperature at
-20°C
.
After 20Min. thermostat will activate the buzzer for 15 times to advise end user that the
pre-cooling cycle is complete.
Note
: , and switch
ON
permanently; +
will be
ON
and will flashing.
3.
The door of blast chiller can be open and store ice cream pans inside the room for a
maximum of 6 pans each time.
4.
Ice Cream cycle will be running for
3.5 Hours
according to setting value of parameter
“rS1”
5.
Once the ice cream cycle is end, thermostat will activate again the buzzer for 15 times to
advise end user that the ice-cream cycle is complete. The device switch automatically to a
storage mode that will keep stored ice cream at a presetting temperature of
-20°C
until
the cycle will stop from end user pressing START/STOP key.
Frost bust cycle (-40°C)
Note
: Needle probe can not be used for the following steps (Air room temperature will be
detected by chamber probe
“rNP”
). This operation is suggested for freeze the surface of stored
food by -40°C
1.
Press and release
Frost bust
key, the led icon will flashing.
2.
Press one time HARD/SOFT key, a Frost Bust (-40°C) cycle will start and icon will be
ON
permanently.
3.
The cycle will ending only once end user will press START/STOP key.
4.
When inner room temperatue reach -40°C compressor will be stopped and will restart
once the interior temperature will reach -37°C (
“rS2”
parameter value)
47
Содержание 45110250
Страница 1: ...Bedienungsanweisung COOL LINE Schnellkühler Schockfroster SKF 5 Easy Art 45110250 2019 12 ...
Страница 3: ...Produktbeschreibung Bezeichnung des Geräts Schockkühler 5 Trays GN und Euronorm 3 ...
Страница 27: ...Sonderzubehör Versetzen des Türanschlags 27 ...
Страница 28: ...Sonderzubehör 28 ...
Страница 33: ...Instruction Manual COOL LINE Blast Chiller SKF 5 Easy Art 45110250 33 ...
Страница 35: ...P2M054STD Ver1 2 GB Product Overview Article Description Blast Chiller N 5 Trays GN and Euronorm 35 ...
Страница 59: ...P2M054STD Ver1 2 GB Optional Accessory How to reverse the door 59 ...
Страница 60: ...P2M054STD Ver1 2 GB Optional Accessory 60 ...
Страница 65: ...Istruzioni d uso Abbattitore SKF 5 Easy Art 45110250 65 ...
Страница 67: ...P2M054STD Ver1 2 IT Panoramica Prodotto Descrizione articolo Abbattitore N 5 Teglie GN e Euronorm 67 ...
Страница 92: ...P2M054STD Ver1 2 IT Accessorio opzionale Come invertire la porta 92 ...
Страница 93: ...P2M054STD Ver1 2 IT Accessorio opzionale 93 ...