Parameter list - inverter functions (selection)
Parameter
Description
Factory
setting
Settings/functions (selection)
P102
Acceleration time
Startup time (acceleration ramp) is the
time corresponding to the linear
frequency rise from 0 Hz to the set
maximum frequency (P105).
[2.00]
Note: Values < 0.1 must be avoided
P103
Deceleration time
Deceleration time (deceleration ramp) is
the time corresponding to the linear
frequency reduction from the set
maximum frequency (P105) to 0 Hz.
[2.00]
Note: Values < 0.1 must be avoided
P104
Minimum
frequency
The minimum frequency is the frequency
supplied by the VFD as soon as it is
enabled and no additional setpoint is
set.
[0]
P105
Maximum
frequency
If the frequency provided by the VFD
after it has been enabled and the
maximum setpoint value is available.
[50]
P200
Motor list
If a 4-pole NORD motor is used, the pre-
set motor data can be called up.
[0]
Select appropriate motor power
P201 – P208
Motor data
If a 4-pole NORD motor is not used, the
motor data on the nameplate must be
entered here.
[xxx]
Data according to nameplate
P220
Parameter
identification
The motor data is automatically
determined by the VFD with this
parameter.
[0]
01= stator resistor only
02 = motor identification
P400
Function, setpoint
inputs
Definition of the functions of the various
setpoint inputs
Input selection:
Potentiometer P1 (P400, [-01]) -
SK 2x5E
Potentiometer P2 (P400, [-02]) -
SK 2x5E
AIN1 (P400, [-01]) - SK 2x0E
AIN2 (P400, [-02]) - SK 2x0E
DIN 2 (P400, [-06])
DIN 3 (P400, [-07])
[xxx]
00 = no function
01 = setpoint frequency
15 = ramp time (P1/P2 only)
P420
Digital input
functions
Definition of the functions of the various
digital inputs
Input selection:
DIN 1 (P420, [-01])
DIN 2 (P420, [-02])
DIN 3 (P420, [-03])
DIN 4 (P420, [-04])
[xxx]
00 = no function
01 = enable right
02 = enable left
04 = fixed frequency 1
05 = fixed frequency 2
26= analog function 0-10 V
(only
DIN2/3)
P428
Automatic start
Inverter enable with "Power On"
[0]
0: off (enable with flank)
1: on (enable with level)
Note:
one digital input must be
programmed and set to enable!
P465
Fixed frequency/
fixed array
Definition of fixed frequency values
Selection:
Fixed frequency 1 (P465, [-01])
Fixed frequency 2 (P465, [-02])
[xxx]
P509
Source control
word
Selection of the interface through which
the VFD is controlled.
[0]
00 = control terminals or keyboard
01 = only control terminals
03 = system bus
P523
Factory setting
Variable Frequency Drive is restored to
the factory setting
[0]
00 = no change
01= load factory setting
Содержание NORDAC FLEX SK 205E Series
Страница 1: ...BU 0240 en US NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters...
Страница 4: ...NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters 4 BU 0240 en US 4920...
Страница 29: ...2 Mounting and installation BU 0240 en US 4920 29 Installation Size 1 3 Size 4...
Страница 97: ...Key word index BU 0240 en US 4920 97...
Страница 98: ...NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters 98 BU 0240 en US 4920...
Страница 99: ...Key word index BU 0240 en US 4920 99...
Страница 100: ...6072403 4920...