7 Technical data
BU 0500 EN-1516
175
Frequency inverter type
SK 5xxE…
-551-323-
-751-323-
-112-323-
-152-323-
-182-323-
Size
5
5
6
7
7
Nominal motor power
(4-pole standard motor)
230 V
5.5 kW
7.5 kW
11.0 kW
15.0 kW
18.5 kW
240 V
7½ hp
10 hp
15 hp
20 hp
25 hp
Mains voltage
230 V
3 AC
200 … 240 V,
±
10 %, 47 … 63 Hz
Input current
rms
30.8 A
39.2 A
64.4 A
84.0 A
102 A
FLA
30.8 A
39.2 A
58.8 A
66.6 A
83.8 A
Output voltage
230 V
3 AC 0 - Mains voltage
Typical output
rms
22.0 A
28.0 A
46.0 A
60.0 A
73.0 A
FLA
22 A
28 A
42 A
54 A
68 A
Min. braking resistor
Accessories
19
Ω
14
Ω
10
Ω
7
Ω
6
Ω
Pulse frequency
range
3 – 16 kHz
Factory setting
6 kHz
Ambient temperature
S1
40 °C.
40 °C.
40 °C.
40 °C.
40 °C.
S3 80 %, 10 min
-
-
-
-
-
S3 70 %, 10 min
-
-
-
-
-
Type of ventilation
Fan cooling, temperature-controlled switching thresholds:
1)
ON= 57°C OFF=47°C
Weight
Approx. [kg]
8
10.3
15
General fuses (AC) (recommended)
slow-blowing
35 A
40 A
80 A
100 A
125 A
Isc
2)
[A]
UL fuses (AC) – permitted
Class
5 000
65 00
0
100 0
00
F
us
e
(600 V)
x
30 A
3)
40 A
3)
60 A
3)
-
-
CC, J, R, T (240 V)
x
30 A
3)
40 A
3)
60 A
3)
-
-
CC, J, R, T, G, L (300 V)
x
-
-
-
100 A
100 A
Bussmann
LPJ-
x x
30SP
40SP
60SP
-
-
CB
(240 V)
x
60 A
3)
60 A
3)
60 A
3)
-
-
(480 V)
x
60 A
3)
60 A
3)
60 A
3)
-
-
(480 V)
x
100 A
100 A
1) Short test run after connection of the mains voltage or control voltage
2) Maximum permissible mains overload current
3) According to mains voltage