SK 500E – Users Manual for Frequency Inverters
182
BU 0500 EN-3021
230V - devices
3 phase operation
Pv module [W]
Max. Rth [K/W]
Cooling area [m²]
1)
SK 5xxE-750-323-A-CP
37.3
0.75
0.38
SK 5xxE-111-323-A-CP
56.7
0.37
0.57
SK 5xxE-151-323-A-CP
67.7
0.31
0.68
SK 5xxE-221-323-A-CP
2)
94.2
0.22
0.95
SK 5xxE-301-323-A-CP
107.5
0.20
1.08
SK 5xxE-401-323-A-CP
147.7
0.14
1.48
1)
Required cooling area, determined under the following general conditions: Control cabinet, height approx. 2 m, ventilation by free
convection, mounting plate: Galvanised sheet steel, not painted, thickness approx. 3 mm.
2)
In contrast to the standard device the SK 5xxE-221-323-A-CP is only available in size 3 for S1-operation.
Table 31: Technical data, ColdPlate 230V devices, three phase operation
3~ 400V- devices
Pv module [W]
Max. Rth [K/W]
Cooling area [m²]
1)
SK 5xxE-550-340-A-CP
15.7
1.78
0.16
SK 5xxE-750-340-A-CP
22.0
1.27
0.23
SK 5xxE-111-340-A-CP
31.1
0.90
0.32
SK 5xxE-151-340-A-CP
42.1
0.66
0.43
SK 5xxE-221-340-A-CP
62.6
0.45
0.63
SK 5xxE-301-340-A-CP
85.7
0.25
0.86
SK 5xxE-401-340-A-CP
115.3
0.18
1.16
SK 5xxE-551-340-A-CP
147.7
0.15
1.48
SK 5xxE-751-340-A-CP
178.0
0.12
1.78
1)
Required cooling area, determined under the following general conditions: Control cabinet, height approx. 2 m, ventilation by free
convection, mounting plate: Galvanised sheet steel, not painted, thickness approx. 3 mm.
Table 32: Technical data, ColdPlate 400V devices