background image

 

21 

 

Specifications 

Environment 

Storage temperature 

 

-30...+60 °C, non-condensing 

Operating temperature 

 

-20...+50 °C 

Operating humidity 

 

5...95 %RH, non-condensing 

Protection class 

 

IP65, except power supply which is IP20 

Enclosure material 

 

Plastic (PC+ABS), silicon rubber 

Compatibility 

Nokeval Sky series 433 MHz ISM band transmitters and optionally 2,4 GHz 
Ovazone series devices. Ovaport network service. 

Measurements 

Weight 

 

About 850 g including the wall holder and an external antenna 

Maximum dimensions 

 

Height 212 mm without the antenna, about 383 mm with the antenna  
Width 134 mm 
Depth 67 mm  

User interface 

LEDs 

 

14 dual-color LEDs 

Buttons  

 

 

2 buttons: power on/off and multifunction button 

Internal memory for buffered results 

Type 

 

Non-volatile FLASH memory 

Capacity 

 

About 500 000 measurements 

Backup batteries 

Type 

 

2 pcs size D heavy-duty alkaline batteries 

Backup running time 

 

About 5 days at +20°C temperature 

 

 

About 8 hours at -20°C temperature 

433.92 MHz radio transceiver (Sky) 

Description 

 

Nokeval Sky protocol and radio transceiver using LoRa modulation 

Antenna 

 

External detachable quarter-wave whip antenna with BNC antenna connector 

Frequency 

 

License-free 433.3…434.5 MHz ERC/REC/70-03 sub-band f 

Power 

 

max 10 dBm E.I.R.P 

Open space range 

 

Up to 10 km, dependent on configuration parameters 

Indoor range 

 

Up to several hundred meters, dependent on configuration parameters 

2.4 GHz radio transceiver (Ovanet) 

Description 

 

Nokeval Ovanet protocol with Wirepas Pino mesh network technology 

Antenna 

 

Internal antenna 

Frequency 

 

2.400-2.485 GHz worldwide license-free ISM band 

Power 

 

max 5 dBm E.I.R.P. 

Open space range 

 

Up to 200 m 

Indoor range 

 

10 to 30 m typical (node to node) 

GSM modem 

Antenna 

 

Internal chip antenna 

Type 

 

Four band EGSM/GPRS/HSDPA (3G) 

SIM card  

 

1.8/3 V auto detect, internal socket, locking mechanism 

Power supply 

Voltage 

 

18...28 VDC 

Current 

 

< 500 mA 

Power 

 

4 pin M12 receptacle, female 

Содержание Cell-Sky-Link-RS485-3G

Страница 1: ...ID9354 V4 5 7 2018 Firmware versions 1 3 0 1 3 0 Cell Sky Link RS485 3G Manual...

Страница 2: ...2 Contents Introduction 3 Installation 5 Configuring the device 8 Usage 17 Maintenance 19 Troubleshooting 20 Specifications 21 Warnings 23 Trademarks 23 Manufacturer 23...

Страница 3: ...mmended interval range When the maximal range is not necessary the parameters should be adjusted for lower battery and band consumption All the devices within one network must share the parameters bec...

Страница 4: ...Hz band However at power up the devices need to find other devices in the network for which a common radio frequency is needed All the devices of the network need to be set to the same radio channel b...

Страница 5: ...led vertically The base station is splash proof but the location must be chosen so that the unit will not be exposed to water or hot steam Please note that the AC socket and the power supply are not s...

Страница 6: ...RS 485 bus D1 pin The diagram below presents the connector pinout looking towards the base station s female connector The same pinout is valid for an opened male connector looking towards the termina...

Страница 7: ...S 485 bus cable should no more than 30 meters long The bus is bidirectional Only one device at a time can send data during which other devices listen Only one device connected to the bus is set as mas...

Страница 8: ...as a 3PIN POL programming connector under the backup battery compartment lid Remove the battery compartment lid to access the programming connector Use POL 3PIN adaptor to connect the DCS772 to the de...

Страница 9: ...9 Menu chart...

Страница 10: ...evices on the same network 1 16777214 Please note that all addresses are not valid Addresses that contain 8 bit sequence 10101010 or 01010101 are not valid If the display shows zero it means that the...

Страница 11: ...dth and spreading factor Config Sky Power 0 10 dBm Output power range Config Sky Channel 1 7 Disabled if effort custom is selected Config Sky Enable Acknowledgement Reserved for future use Config Sky...

Страница 12: ...dbus WXT5x0 Ascii SCL Choose Modbus Config Serial communication Baud rate 300 600 1200 2400 4800 9600 19200 38400 57600 115200 230400 Choose the desired baud rate Config Serial communication Bits 8N1...

Страница 13: ...ings are incorrect Limited Only part of the sequential results is fetched because virtual ID has overlapping with some other Modbus query or internal status result Blocked The result is not fetched be...

Страница 14: ...e maximum is 62 Config Serial communication Query x Data type Sint 16 bit Uint 16 bit Sint 32 bit BE Uint 32 bit BE Sint 32 bit LE Uint 32 bit LE Float BE Float LE Bit field Data type type when regist...

Страница 15: ...l ID has overlapping with some other Modbus query or internal status result Unrecognized data Modbus reply is wrong type or wrong length Timeout Modbus replay was not received Exception Modbus device...

Страница 16: ...t Register Register 1000 Results 3 Data type Sint 16 bit Divider 10 Virtual ID 3 Status OK 15 3 Example of the Modbus settings for TTM20X Config Modbus Query 3 Slave 2 Register Type Holding Register R...

Страница 17: ...has 3G connection Solid yellow GSM modem has 2G connection Blinks red GSM modem replies Registration denied Solid red GSM modem is unable to communicate with the internal processor SRV Off There is no...

Страница 18: ...tates the following LEDs are turned off RS485 RF2 RF1 SRV GSM Will return to normal state automatically in 30 s F2 Long press of the multifunction button will trigger an OTA firmware update if update...

Страница 19: ...ket It can be cleaned by wiping with a damp cloth The device is not meant to be immersed into water or other liquids Service If Bat LED indicates low battery voltage red see above BAT LED the backup b...

Страница 20: ...was not successful Backup battery level needs to be above certain level to start the search for the new firmware If the search will not start replace the batteries and try to find a place with a bette...

Страница 21: ...teries Backup running time About 5 days at 20 C temperature About 8 hours at 20 C temperature 433 92 MHz radio transceiver Sky Description Nokeval Sky protocol and radio transceiver using LoRa modulat...

Страница 22: ...ware update Over The Air OTA firmware update RS485 external connector pins Modbus RTU or Nokeval SCL protocols Cloud connection Compatibility Nokeval Ovaport cloud service GSM connectivity 2G or 3G EG...

Страница 23: ...e like in a parked car where temperature can rise to over 50 C The battery may overheat and cause fire or explosion hazard Read this manual carefully before using the device Only Nokeval authorized se...

Отзывы: