Usage 

The base station will not require any continuous operation or intervention by the user. The device 

works independently and will not usually require attention after installation. However, from time to 
time, check that the device is still functional. 

Multifunction button    

In normal mode, LED bar indicates GSM signal strength. Short press of the multifunction button 
switches the LED bar to indicate the RAM buffer consumption. Second short press switches the LED bar 

to indicate FLASH memory consumption. Third press returns the LED bar to indicate GSM signal 
strength again. See below LED F1. 

Long press of the multifunction button sets the device to firmware OTA update mode. See below LED 
F2. 

If the battery low alarm sounds, it can be acknowledged and muted by a short press of the 
multifunction button. See below LED BAT. 

LEDs 

GSM 

Blinks green 

GSM-modem is starting up. 

Blinks yellow 

There is no SIM-card in place. 

Solid green 

GSM-modem has 3G connection. 

Solid yellow 

GSM-modem has 2G connection. 

Blinks red 

GSM-modem replies: Registration denied. 

Solid red 

GSM-modem is unable to communicate with the internal processor. 

SRV 

Off 

There is no IP-address. 

Blinks yellow 

Base station tries to connect to Ovaport. 

Blinks green 

Base station in connection to Ovaport and tries to "handshake". 

Solid green 

Base station in connection to Ovaport and handshake is successful. 

RF1 

Blinks green about every 10 s  Received a packet from a Sky radio (433 MHz) within 1 min 30 s. 
Solid yellow 

There are packets in the FLASH memory buffer that haven’t been 

sent to Ovaport (also blinks green every 10 s if new packets arrive). 

Solid red 

FLASH memory buffer is full (also blinks green every 10 s if new 
packets arrive). 

RF2 

Blinks green about every 10 s  Received a packet from the Ovanet radio network (2,4 GHz) within 

1 min 30 s. 

Off 

No neighbours found in the Ovanet radio network. 

Blinks yellow about every 10 s  The base station has neighbours (transit to blink green, once it gets 

measurement packets). 

Solid red 

Ovanet radio signals an error or internal processor cannot 

communicate with the Ovanet processor. 

 

 

Содержание Cell-Sky-Link-RS485-3G

Страница 1: ...ID9354 V4 5 7 2018 Firmware versions 1 3 0 1 3 0 Cell Sky Link RS485 3G Manual...

Страница 2: ...2 Contents Introduction 3 Installation 5 Configuring the device 8 Usage 17 Maintenance 19 Troubleshooting 20 Specifications 21 Warnings 23 Trademarks 23 Manufacturer 23...

Страница 3: ...mmended interval range When the maximal range is not necessary the parameters should be adjusted for lower battery and band consumption All the devices within one network must share the parameters bec...

Страница 4: ...Hz band However at power up the devices need to find other devices in the network for which a common radio frequency is needed All the devices of the network need to be set to the same radio channel b...

Страница 5: ...led vertically The base station is splash proof but the location must be chosen so that the unit will not be exposed to water or hot steam Please note that the AC socket and the power supply are not s...

Страница 6: ...RS 485 bus D1 pin The diagram below presents the connector pinout looking towards the base station s female connector The same pinout is valid for an opened male connector looking towards the termina...

Страница 7: ...S 485 bus cable should no more than 30 meters long The bus is bidirectional Only one device at a time can send data during which other devices listen Only one device connected to the bus is set as mas...

Страница 8: ...as a 3PIN POL programming connector under the backup battery compartment lid Remove the battery compartment lid to access the programming connector Use POL 3PIN adaptor to connect the DCS772 to the de...

Страница 9: ...9 Menu chart...

Страница 10: ...evices on the same network 1 16777214 Please note that all addresses are not valid Addresses that contain 8 bit sequence 10101010 or 01010101 are not valid If the display shows zero it means that the...

Страница 11: ...dth and spreading factor Config Sky Power 0 10 dBm Output power range Config Sky Channel 1 7 Disabled if effort custom is selected Config Sky Enable Acknowledgement Reserved for future use Config Sky...

Страница 12: ...dbus WXT5x0 Ascii SCL Choose Modbus Config Serial communication Baud rate 300 600 1200 2400 4800 9600 19200 38400 57600 115200 230400 Choose the desired baud rate Config Serial communication Bits 8N1...

Страница 13: ...ings are incorrect Limited Only part of the sequential results is fetched because virtual ID has overlapping with some other Modbus query or internal status result Blocked The result is not fetched be...

Страница 14: ...e maximum is 62 Config Serial communication Query x Data type Sint 16 bit Uint 16 bit Sint 32 bit BE Uint 32 bit BE Sint 32 bit LE Uint 32 bit LE Float BE Float LE Bit field Data type type when regist...

Страница 15: ...l ID has overlapping with some other Modbus query or internal status result Unrecognized data Modbus reply is wrong type or wrong length Timeout Modbus replay was not received Exception Modbus device...

Страница 16: ...t Register Register 1000 Results 3 Data type Sint 16 bit Divider 10 Virtual ID 3 Status OK 15 3 Example of the Modbus settings for TTM20X Config Modbus Query 3 Slave 2 Register Type Holding Register R...

Страница 17: ...has 3G connection Solid yellow GSM modem has 2G connection Blinks red GSM modem replies Registration denied Solid red GSM modem is unable to communicate with the internal processor SRV Off There is no...

Страница 18: ...tates the following LEDs are turned off RS485 RF2 RF1 SRV GSM Will return to normal state automatically in 30 s F2 Long press of the multifunction button will trigger an OTA firmware update if update...

Страница 19: ...ket It can be cleaned by wiping with a damp cloth The device is not meant to be immersed into water or other liquids Service If Bat LED indicates low battery voltage red see above BAT LED the backup b...

Страница 20: ...was not successful Backup battery level needs to be above certain level to start the search for the new firmware If the search will not start replace the batteries and try to find a place with a bette...

Страница 21: ...teries Backup running time About 5 days at 20 C temperature About 8 hours at 20 C temperature 433 92 MHz radio transceiver Sky Description Nokeval Sky protocol and radio transceiver using LoRa modulat...

Страница 22: ...ware update Over The Air OTA firmware update RS485 external connector pins Modbus RTU or Nokeval SCL protocols Cloud connection Compatibility Nokeval Ovaport cloud service GSM connectivity 2G or 3G EG...

Страница 23: ...e like in a parked car where temperature can rise to over 50 C The battery may overheat and cause fire or explosion hazard Read this manual carefully before using the device Only Nokeval authorized se...

Отзывы: