OPERATION

7

SpeedScrub Rider 331140 (9- 2013)

HOW THE MACHINE WORKS

The scrub components of the machine are a

solution tank, scrub brushes or pads, a squeegee,

a vacuum fan, and a recovery tank.

The buttons on the control panel control the

machine scrubbing functions. The

One Step

Scrub button

turns the preset scrub functions on

and off. The FaST button (option) enables the

FaST (Foam Scrubbing Technology) system. The

ec- H2O

button (option) enables the

ec- H2O

(electrically converted water) system. The

vacuum fan / squeegee button

turns the vacuum

fan on/off and raises and lowers the squeegee.

The

brush pressure buttons

control the scrub

brush pressure, and the

solution buttons

control

the solution flow.

The

steering wheel

controls the path of the

machine travel. The

directional switch

controls the

forward or reverse direction of the machine. The

propel pedal controls the speed of the machine.

The

brake pedal

slows and stops the machine.

There are two different types of scrub heads

available, cylindrical and disk. Both scrub heads

are available in two different widths. The Disk

scrub head is available in 650 mm (26 in) wide and

800 mm (32 in) wide. The Cylindrical scrub head is

available in 700 mm (28 in) wide and 800 mm

(32 in) wide.

NOTE

:

The amount and type of soilage play an

important role in determining the type of brushes

or pads to use. For specific recommendations,

see the BRUSH INFORMATION section of this

manual or contact a Tennant representative.

CONVENTIONAL SCRUBBING

Water and detergent from the solution tank flow to

the floor through a solution valve. The brushes

use the detergent and water solution to scrub the

floor clean. As the machine propels forward, the

squeegee wipes the dirty solution from the floor.

The suction created by the vacuum fan then

draws the dirty solution from the squeegee into

the recovery tank.

FOAM SCRUBBING SYSTEM (FaST MODEL)

Unlike conventional scrubbing, the optional FaST

(Foam Scrubbing Technology) system operates

by injecting the FaST- PAK concentrate agent into

the system with a small amount of water and air.

This mixture creates a large volume of expanded

wet foam.

The expanded foam mixture is then dispersed

onto the floor while the machine is scrubbing.

When the squeegee picks up the mixture, the

patented foaming agent has collapsed and is

recovered into the recovery tank.

The FaST system can be used with all double

scrubbing and heavy duty scrubbing applications.

Using the FaST system improves safety and can

increase productivity by 30% by reducing your

dump/fill cycle. It will also reduce chemical usage

and storage space. One FaST- PAK of

concentrated agent can scrub up to 90,000 m

2

(1

million square feet).

NOTE: Do not use the FaST system with

conventional cleaning detergents in the solution

tank. Drain, rinse and refill the solution tank with

clear cool water before operating the FaST

system. Conventional cleaning detergents may

cause failure to the FaST system.

Содержание Speed Scrub Rider

Страница 1: ...SCRUBBER R R The Safe Scrubbing Alternativer Quick Traint Controls Hygenic Fully Cleanable Tanks TennantTrue Parts IRIS a Tennant Technology OPERATOR MANUAL For the latest Parts manuals and other lan...

Страница 2: ...tions Always remember to recycle Model No Serial No Installation Date Please fill out at time of installation for future reference MACHINE DATA INTENDED USE The Speed Scrub Rider is an industrial comm...

Страница 3: ...intenance Free Batteries 28 Checking Connections Cleaning 28 Charging The Batteries With Off Board Charger 29 Checking On Board Battery Charger Settings 30 Page Battery Select Mode 30 Charging The Bat...

Страница 4: ...emicals known to the state of California to cause cancer birth defects or other reproductive harm FOR SAFETY 1 Do not operate machine Unless trained and authorized Unless operator manual is read and u...

Страница 5: ...h battery acid Battery installation must be done by trained personnel All repairs must be performed by a trained service mechanic Do not modify the machine from its original design Use Tennant supplie...

Страница 6: ...t to foot pedals Located on electrical panel under the seat WARNING LABEL Batteries emit hydrogen gas Explosion or fire can result Keep sparks and open flame away Keep covers open when charging WARNIN...

Страница 7: ...D Operator seat E Batteries F Rear squeegee G Side squeegee H Scrub head I Steering wheel J Solution tank K Tool Box or optional FaST PAK compartment ec H2O System Module option L Solution tank fill...

Страница 8: ...indicators D Fault indicator E Emergency Stop Button F Directional switch G Horn button H On Off key switch I One Step scrub button J FaST button option ec H2O system on off switch option K ec H2O sy...

Страница 9: ...ions see the BRUSH INFORMATION section of this manual or contact a Tennant representative CONVENTIONAL SCRUBBING Water and detergent from the solution tank flow to the floor through a solution valve T...

Страница 10: ...ose polypropylene bristle to lift lightly compacted soilage without scuffing high gloss coated floors Nylon brush Cylindrical and Disk Softer nylon bristles are recommended for scrubbing coated floors...

Страница 11: ...NanoClean model ec H2O models labeled ec H2O NanoClean The ec H2O system is equipped with a water conditioning cartridge The cartridge is designed to protect the machine s plumbing system from potenti...

Страница 12: ...arton Do Not remove the bag from the carton Pull out the hose connector located on the bottom of the bag and remove the hose cap from the connector NOTE The FaST PAK Floor Cleaning Concentrate is spec...

Страница 13: ...s warranty MACHINE OPERATION PRE OPERATION CHECKLIST Check the machine for fluid leaks Check the battery fluid and charge level Check the tank cover seals for damage and wear Clean the vacuum fan inle...

Страница 14: ...the brush pressure should be set to the minimum setting the bottom light Under heavy grime conditions the brush pressure should be set to the maximum setting the top light Travel speed and floor condi...

Страница 15: ...c H2O NanoClean models contact an Authorized Service Center if solution flow rate adjustment is required SCRUBBING FOR SAFETY Do not operate machine unless operator manual is read and understood 1 Tur...

Страница 16: ...scrubbing WARNING Flammable materials or reactive metals can cause an explosion or fire Do not pick up 7 Release the propel pedal to stop the machine Scrubbing functions stop and the automatic park b...

Страница 17: ...le scrub press the One Step Scrub button then the vacuum fan button The light above the vacuum fan button will turn off the squeegee will raise and the vacuum fan will stop operating Then scrub the ar...

Страница 18: ...ad end aisles start at the closed end of the aisle and scrub out towards the opening Adjust the machine speed brush pressure and solution flow as required when scrubbing Use the minimal brush pressure...

Страница 19: ...INDICATOR LIGHT The ec H2O system indicator light will not turn on until the machine starts scrubbing ec H2O NanoClean Models ec H2O models labeled ec H2O NanoClean ec H2O SYSTEM INDICATOR LIGHT CODE...

Страница 20: ...ter or solution BATTERY DISCHARGE INDICATOR The battery discharge indicator shows the charge level of the batteries When the batteries are fully charged all five lights are lit As the batteries discha...

Страница 21: ...resentative Fault Light and top Brush Pressure Light both blink The right or rear Brush Motor is overloaded possibly from string or banding wrapped around motor Remove string banding from motor or Con...

Страница 22: ...blem is corrected The circuit breakers are located inside the battery compartment next to the hour meter The chart shows the circuit breakers and the electrical components they protect Circuit Breaker...

Страница 23: ...operator seat forward and hook the seat latch into place to hold up the seat 4 Remove the recovery tank drain hose While holding the hose up remove the plug then slowly lower the drain hose to the fl...

Страница 24: ...oor drain or sink 11 Tilt the recovery tank back to access the solution tank Make sure the recovery tank is empty before tilting 12 Flush the solution tank and rinse the float sensor located inside th...

Страница 25: ...r in seat Sit in seat when operating machine Horn repeatedly beeps 4 times ON OFF key switch is turned on while propel pedal is engaged Release the propel pedal before turning key on Horn repeatedly b...

Страница 26: ...ry tank Empty recovery tank Use less detergent Recovery tank sensor dirty or stuck Clean or replace sensor Little or no solution flow to the floor Conventional Scrubbing Mode Solution tank empty Fill...

Страница 27: ...r light blinking green red Water conditioning cartridge has expired Replace cartridge See ec H2O NanoClean WATER CONDITIONING CARTRIDGE REPLACEMENT ec H2O system indicator is red or blinking red ec H2...

Страница 28: ...MAINTENANCE 26 SpeedScrub Rider 331140 02 09 MAINTENANCE 1 1 2 8 3 9 11 5 4 3 6 3 10 7 10 3 12 13 14 355033 15...

Страница 29: ...batteries Check electrolyte level DW 3 50 Hours O 11 Disk scrub head floor skirt Check for damage and wear 2 O 13 Cylindrical brushes Check taper and rotate front to rear 2 100 Hours T 3 Vacuum Fan an...

Страница 30: ...level weekly NOTE Do Not check the electrolyte level if the machine is equipped with a battery watering system 08247 FOR SAFETY When servicing machine keep all metal objects off batteries Avoid conta...

Страница 31: ...battery charging connector WARNING Batteries emit hydrogen gas Explosion or fire can result Keep sparks and open flame away Keep covers open when charging 5 Plug the battery charger into the wall out...

Страница 32: ...must be unplugged when resetting After charger is properly set for battery type run the Battery Select Mode See BATTERY SELECT MODE Acd wet lead acid battery GEL sealed AGM maintenance free battery B...

Страница 33: ...t U Battery Voltage h Charging time C Charging ampere hours Ah E Energy used Kwh 6 Press the arrow button to review the codes Once the charging cycle begins the indicator lights will progress from red...

Страница 34: ...hours of machine operation and then every 100 hours after the initial 500 hours BELTS Cylindrical Models FOR SAFETY Before leaving or servicing machine stop on level surface turn off machine and remov...

Страница 35: ...place by a pad holder Cleaning pads need to be cleaned immediately after use with soap and water Do not wash the pads with a pressure washer Hang pads or lie pads flat to dry NOTE Always replace brush...

Страница 36: ...or hub and push it upward to engage hub Ensure that it is securely mounted onto the motor hub 8 Close the side squeegee and the retainer pivot then insert the pin NOTE Be sure the pin is inserted comp...

Страница 37: ...h off FOR SAFETY Before leaving or servicing machine stop on level surface turn off machine and remove key 3 Remove the cotter pin that holds the side squeegee in place Swing the squeegee away from th...

Страница 38: ...owly press the propel pedal until the scrub brushes start spinning Allow the machine to scrub in the same place for 15 to 20 seconds 5 Raise the scrub head and drive the machine away from the chalked...

Страница 39: ...he cotter pin that holds the side squeegee in place Swing the squeegee away from the scrub head 4 Remove idler plate from the scrub head by pressing the spring tab downward 5 While holding the flat en...

Страница 40: ...y switch off FOR SAFETY Before leaving or servicing machine stop on level surface turn off machine and remove key 3 Loosen the two scrub head mounting screws 4 Loosen the jam nut then adjust the brush...

Страница 41: ...tor assembly is located on top of the scrub head new photo Disk Model Cylindrical Brush Model 2 Remove the injector assembly from the pinch clamps 3 Replace the water and air filter An 8mm hex wrench...

Страница 42: ...compartment shroud from machine to access cartridge 3 Disconnect the two hose connectors from cartridge by pressing the gray collars inward and pulling the connectors outward Lift cartridge to remove...

Страница 43: ...between 4 8 Do not use other acids for this procedure 3 Disconnect the black connector fitting at the scrub head and place the hose into a bucket 4 Turn the key to the on position 5 Press and release...

Страница 44: ...be removed from the squeegee pivot to prevent damage during transport of the machine REPLACING OR ROTATING THE REAR SQUEEGEE BLADES 1 Stop machine on a level surface Make sure the scrub head is in the...

Страница 45: ...abs on the squeegee assembly 11 Reinstall the rear squeegee retaining band onto the squeegee assembly Be sure each of the flanges on the retaining band are seated in the cut outs in the rear squeegee...

Страница 46: ...e assures the entire length of the squeegee is in even contact with the surface being scrubbed Perform this adjustment on an even and level floor 1 Lower the squeegee and drive the machine forward a f...

Страница 47: ...h FOR SAFETY Before leaving or servicing machine stop on level surface turn off machine and remove key 3 Look at the amount of deflection or curl of the squeegee blade The correct amount of deflection...

Страница 48: ...y The recovery tank seal is located on the bottom of the recovery tank cover Check the seal for damage and wear after every 100 hours of operation SOLUTION TANK SEALS FOR SAFETY Before leaving or serv...

Страница 49: ...n transporting the machine by trailer or truck be certain to follow the tie down procedure below 1 Raise the squeegee and scrub head FOR SAFETY When loading unloading machine onto off truck or trailer...

Страница 50: ...ool dry area Do not expose the machine to rain Store indoors FREEZE PROTECTION FOR SAFETY Before leaving or servicing machine stop on level surface and turn off machine 1 Drain the solution tank and r...

Страница 51: ...machine stop on level surface and turn off machine 1 Drain the antifreeze from the solution tank into a bucket 2 Fill the solution tank with cool water until full See FILLING THE SOLUTION TANK 3 Disc...

Страница 52: ...386 Kg 850 lbs 407 kg 897 lbs 386 Kg 850 lbs 416 kg 918 lbs Weight with heavy duty battery package 443 Kg 975 lbs 464 kg 1022 lbs 443 Kg 975 lbs 473 kg 1043 lbs GVWR 675 Kg 1485 lbs Protection Grade...

Страница 53: ...24 20 50 60 1 240 Chargers On Board 24 25 50 60 1 115 TIRES Location Type Size Front 1 Solid 90 mm wide x 260 mm OD 3 5 in wide x 10 in OD Rear 2 Solid 80 mm wide x 260 mm OD 3 0 in wide x 10 in OD Fa...

Страница 54: ...Rider 331140 9 06 52 Frame Cyl 810 mm 31 7 in 1270 mm 50 in 1520 mm 60 in For 650 mm 26 in and 700 mm 28 in squeegee 800 mm 33 25 in For 800 mm 32 in squeegee 1000 mm 39 25 in Frame Disk 740 mm 29 in...