21
c.
Check and refill hydraulic oil
The required hydraulic l type is:
•
H-LP 46, DIN 51524
•
Viscosity is 41.4
– 47
•
Oil volume: 10L
Waste material like used oil, waste batteries or others must be properly disposed and recycled
according to the national regulations and if necessary brought to a recycling company.
The oil level in the oil tank should not be under the min marks for starting the stacker.
d.
Check the electrical fuses
Remove the front panel, the fuses are located as shown in the following figure Fig. 14. The
specification of the fuses are shown in the table 4.
Table 4: Specification of the fuses
Specification
FU01
150A
FU02
200A
FU1
10A
FU2
15A
Fig. 14: Location of fuses
Содержание PS12/15CB-C
Страница 4: ...4 c Technical data for US market 30 12 DECLARATION OF CONFORMITY valid if sold within the EU 32...
Страница 7: ...7 b Main technical data Fig 2 Technical data...
Страница 25: ...25 b Hydraulic circuit diagram Fig 16 Hydraulic circuit diagram without tilting...
Страница 26: ...26 Fig 17 Hydraulic circuit diagram with tilting...